Literature DB >> 28086245

Use of All-polyethylene Tibial Components in Unicompartmental Knee Arthroplasty Increases the Risk of Early Failure.

In Jun Koh1,2, Kyung Hwan Suhl3, Min Woo Kim4, Man Soo Kim1, Keun Young Choi1, Yong In1,2.   

Abstract

All-polyethylene (all-poly) tibial designs in primary total knee arthroplasty (TKA) have been reconsidered with excellent clinical outcomes, survivorship, and cost-effectiveness. However, whether all-poly tibial components provided comparable results to metal-backed modular components during unicompartmental knee arthroplasty (UKA) remains unclear. This study compared the clinical outcomes and prevalence of early failure between all-poly and metal-backed modular components in UKA. We retrospectively reviewed the records and radiographs of 101 consecutive UKAs. In total, 51 UKAs were performed using all-poly tibial components; 50 others used metal-backed modular components. Clinical and radiographic outcomes, adaptive bone remodeling assessed by radiographic bone density, and early failure prevalence rates were compared. Despite a lack of group differences in clinical and radiographic outcomes (p > 0.1 in all comparisons), adaptive bone remodeling at 2 years after surgery of all-poly UKAs was more progressive compared with metal-backed UKAs (1.2 in all-poly UKA group vs. 0.9 in metal-backed UKA group, p < 0.001). In addition, 6 of 51 all-poly UKAs failed within 2 years postoperatively, whereas no metal-backed UKAs failed (11% in all-poly UKA group vs. 0% in metal-backed UKA group, p = 0.027). All-poly tibial component use during UKA increased the risk of early failure, which may be due to a failure in tibial loading distribution. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28086245     DOI: 10.1055/s-0036-1597979

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  6 in total

1.  All-polyethylene unicompartmental knee arthroplasty is associated with increased risks of poorer knee society knee score and lower satisfaction in obese patients.

Authors:  Wayne Yong Xiang Foo; Ming Han Lincoln Liow; Jerry Yongqiang Chen; Darren Keng Jin Tay; Ngai Nung Lo; Seng Jin Yeo
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-30       Impact factor: 3.067

2.  Unicompartmental knee arthroplasty: all-poly versus metal-backed tibial component-a long-term follow-up study.

Authors:  Vincenzo Sessa; Umberto Celentano
Journal:  Int Orthop       Date:  2021-04-20       Impact factor: 3.075

3.  Do Fixed or Mobile Bearing Implants Have Better Survivorship in Medial Unicompartmental Knee Arthroplasty? A Study From the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Arun Kannan; Peter L Lewis; Chelsea Dyer; William A Jiranek; Stephen McMahon
Journal:  Clin Orthop Relat Res       Date:  2021-07-01       Impact factor: 4.755

4.  Ten-year survival and patient-reported outcomes of a medial unicompartmental knee arthroplasty incorporating an all-polyethylene tibial component.

Authors:  Chloe E H Scott; Frazer A Wade; Deborah MacDonald; Richard W Nutton
Journal:  Arch Orthop Trauma Surg       Date:  2018-02-23       Impact factor: 3.067

5.  Unicompartmental knee arthroplasty: Current indications, technical issues and results.

Authors:  E Carlos Rodríguez-Merchán; Primitivo Gómez-Cardero
Journal:  EFORT Open Rev       Date:  2018-06-06

Review 6.  Comparable incidence of periprosthetic tibial fractures in cementless and cemented unicompartmental knee arthroplasty: a systematic review and meta-analysis.

Authors:  Joost A Burger; Tjeerd Jager; Matthew S Dooley; Hendrik A Zuiderbaan; Gino M M J Kerkhoffs; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-02-02       Impact factor: 4.342

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.