His-Bundle Pacing for Identifying Optimal Ablation Sites in Patients Undergoing Atrioventricular Junction Ablation: Teaching an Old Dog a New Trick.

Nitin Kulkarni1, Curtiss Moore1, Ambarish Pandey1, Demetrio Castillo1, Colby Ayers1,2, Jose Joglar1, Richard Wu1.   

Abstract

BACKGROUND: Atrioventricular (AV) junction (AVJ) ablation is conventionally performed by localizing the His-bundle electrogram (HBE). Identification of HBE in the presence of atrial fibrillation (AF) can be difficult, and can make this simple procedure challenging. In this study, we describe our experience with an alternative approach to localize optimal ablation sites using His-bundle pacing (HBP).
METHODS: Between 1/1/2014 and 12/31/2015, we performed 13 AVJ ablations using the standard electrogram-guided approach and 11 ablations using HBP. All cases utilized a long femoral guiding sheath and an 8-mm-tip electrode radiofrequency (RF) energy ablation catheter. Pacing was performed at high output (10 mA at 2 ms) to initially achieve right bundle branch capture. The catheter was withdrawn until a narrow QRS morphology and increased stim-to-QRS time were observed. HBP was confirmed when paced and native QRS were identical in morphology. RF energy was applied at the site of HBP capture until AV block was observed.
RESULTS: Baseline characteristics of patients in each arm were not significantly different. Compared with the standard approach, HBP was associated with trends toward lower RF applications (3 vs. 2, P = 0.16) and shorter mean RF time (208 seconds vs. 128 seconds, P = 0.19).
CONCLUSION: HBP is an effective technique to identify optimal ablation sites during AVJ ablation and may shorten procedure time. HBP can be used to identify the AV node during AF without recording the His potential. Future studies with larger sample size are needed to better characterize the utility of this technique.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  AVJ junction ablation; AVN node ablation; atrial fibrillation; his-bundle pacing

Mesh:

Year:  2017        PMID: 28084626     DOI: 10.1111/pace.13019

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

Review 1.  Should His Bundle Pacing Be Preferred over Cardiac Resynchronization Therapy Following Atrioventricular Junction Ablation?

Authors:  Zak Loring; Albert Y Sun
Journal:  Cardiol Clin       Date:  2019-02-10       Impact factor: 2.213

2.  The Role of High-output His-bundle Pacing During Atrioventricular Node Ablation.

Authors:  Khalil Kanjwal; Wasim Rashid; Asim Kichloo; Abdul Qadir Haji
Journal:  J Innov Card Rhythm Manag       Date:  2022-07-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.