Literature DB >> 28081865

The outcome of super-cutaneous locked plate fixation with percutaneous reduction of displaced intra-articular calcaneal fractures.

Ihab I El-Desouky1, Wissam Abu Senna2.   

Abstract

INTRODUCTION: Supercutaneous (external) fixation with locking plate is utilized for fixation of long bone fractures. One retrospective study for open reduction and supercutaneous fixation of the calcaneus is reported. We prospectively evaluated the use of this method of fixation combined with percutaneous reduction.
MATERIALS AND METHODS: Between January 2014 and June 2015, 32 displaced calcaneus fractures in 30 patients were stabilized with percutaneous reduction and super-cutaneous fixation. They were 24 males and six females. The mean age was 37.9±5.7 years (21-55). All cases were closed. The time to surgery, complications, radiographic alignment, and time to radiographic union were recorded. Clinical results at the final follow-up were assessed by evaluating Bohler's angles for the radiographic alignment, and the system of the American Orthopedic Foot and Ankle Society (AOFAS) for the functional outcome.
RESULTS: According to the Sanders' classification, two cases were type II, 17 cases were type III and 13 cases were type IV. The preoperative average Bohler's angle was 10.57°±4.8. The postoperative X-ray films demonstrated that the average Bohler's angle improved to 29.07°±5.9 (p<0.001). At the time of radiologic healing (about 3 months), the plates and screws were removed under general anesthesia. The average follow-up was 13.2 months (11-18). Four cases (type IV) showed mal-union and heel pain. According to (AOFAS) rating, the fine score was 87.1±17.1 points.
CONCLUSION: Super-cutaneous fixation with percutaneous reduction of calcaneal fracture is an effective method in type II and III and can be effective with type IV but with less favorable results.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Calcaneus; Locked plate; Percutaneous reduction; Supercutaneous fixation

Mesh:

Year:  2017        PMID: 28081865     DOI: 10.1016/j.injury.2017.01.014

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  2 in total

1.  The Comparison of Clinical Efficacy of Minimally Invasive Tarsal Sinus Approach and L-Type Incision Approach Combined with 3D Printing Technology in Calcaneal Fracture.

Authors:  Hao Du; Shiang Li; Shicheng Tu; Kun Wang; Zhiyu Fang
Journal:  Comput Math Methods Med       Date:  2022-07-11       Impact factor: 2.809

2.  Sanders type 3-4 calcaneal fractures fixed with locking plate: does tri-cortical iliac bone autograft provide extra benefit for stabilization?

Authors:  Tugrul Bulut; Merve Gursoy; Tahir Ozturk; Cem Ozcan; Muhittin Sener
Journal:  Ther Clin Risk Manag       Date:  2018-09-11       Impact factor: 2.423

  2 in total