Literature DB >> 28081789

Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS.

Xiao-Pen Lee1, Yukiko Shouji2, Takeshi Kumazawa3, Chika Hasegawa4, Masaya Fujishiro2, Junichi Sato2, Iwao Hasegawa5, Keizo Sato2.   

Abstract

A high-throughput method was developed for the detection of 31 benzodiazepine drugs and tandospirone in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry. Plasma samples (100μl) spiked with the 32 drugs and oxazepam-d5 (internal standard) were diluted with 300μl of 13.3mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced into an analytical column (SUMIPAX ODS D-Swifter column, 30mm×3.0mm i.d.; particle size 2μm) by column switching. Quantification was performed by multiple reaction monitoring with positive-ion electrospray ionization. Distinct peaks appeared for each drug and the internal standard on each channel within 7min, including the extraction time. All drugs spiked into plasma showed recoveries of 83-95%. The regression equations for the 32 drugs showed excellent linearities in the range of 50-2000pg/ml of plasma and the limits of detection ranged from 20 to 50pg/ml. The lower and upper limits of quantitation were 50-100ng/ml and 2000pg/ml, respectively. Intra- and interday coefficients of variation for none of the drugs were greater than 13.6%. The accuracies of quantitation were 87-112%. The multiple reaction monitoring information-dependent acquisition of enhanced product ions method enabled the quantification and confirmation of diazepam, triazolam, and lorazepam obtained from actual plasma.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Benzodiazepine drugs; Human plasma; On-line column switching; SUMIPAX ODS D-Swifter column; Tandospirone; UFLC-MS/MS

Mesh:

Substances:

Year:  2016        PMID: 28081789     DOI: 10.1016/j.legalmed.2016.11.005

Source DB:  PubMed          Journal:  Leg Med (Tokyo)        ISSN: 1344-6223            Impact factor:   1.376


  2 in total

1.  A high-throughput bioanalytical assay to support pharmacokinetic interaction study of oxycodone and diazepam in Sprague Dawley rats.

Authors:  Nageswara R Pilli; Suresh Narayanasamy; Lin Xu; Ashok Chockalingam; Katherine I Shea; Sharron Stewart; Rodney Rouse; Vikram Patel; Murali K Matta
Journal:  RSC Adv       Date:  2020-01-03       Impact factor: 4.036

2.  Development of a simple and sensitive HPLC-MS/MS method for determination of diazepam in human plasma and its application to a bioequivalence study.

Authors:  Do-Hyung Kim; Ji-Yoon Cho; Soo-In Chae; Bo-Kyung Kang; Tae-Gil An; Wang-Seob Shim; Young Su Noh; Se Jung Hwang; Eun Kyoung Chung; Kyung-Tae Lee
Journal:  Transl Clin Pharmacol       Date:  2017-12-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.