Literature DB >> 28079618

Diffusion-weighted MRI Enables to Accurately Grade Inflammatory Activity in Patients of Ileocolonic Crohn's Disease: Results from an Observational Study.

Xue-Hua Li1, Can-Hui Sun, Ren Mao, Si-Yun Huang, Zhong-Wei Zhang, Xu-Feng Yang, Li Huang, Jin-Jiang Lin, Jian Zhang, Shomron Ben-Horin, Shi-Ting Feng, Min-Hu Chen, Zi-Ping Li.   

Abstract

BACKGROUND: Diffusion-weighted imaging (DWI) is a novel technique to evaluate bowel inflammation in Crohn's disease (CD). It remains unclear whether DWI could differentiate grades of inflammation activity and add to the accuracy of conventional magnetic resonance enterography (MRE) in defining disease activity. We aimed to assess the accuracy of DWI for evaluating ileocolonic CD inflammation compared with conventional MRE, using ileocolonoscopy as reference standard.
METHODS: This was an observational study of CD patients who underwent both ileocolonoscopy and MRE with DWI. The conventional MRE and DWI findings of the ileocolon were scored from 0 to 3. The respective segment endoscopic disease activity was scored by simplified endoscopic score for Crohn's disease (SES-CD) and was graded as inactive (0-2), mild (3-6) or moderate-severe (≥7).
RESULTS: One hundred eighty-five bowel segments from 43 consecutive CD patients were evaluated and included inactive (n = 86), mild (n = 72), and moderate-severe (n = 27) ileo-colonic segments. The area under the receiver operating characteristics curve (AUC) of 0.973 for apparent diffusion coefficient (ADC) to differentiate active from inactive CD was significantly higher than those of conventional MRE parameters (AUC between 0.840 and 0.940). Higher accuracy of ADC (AUC = 0.919) for differentiating inactive-mild from moderate-severe CD was also shown compared with that of conventional MRE parameters (AUC between 0.868 and 0.915). ADC values demonstrated strongest correlation with SES-CD (r = -0.880) comparing to DWI SI and conventional MRE parameters (r between 0.787 and 0.867).
CONCLUSIONS: DWI enables to accurately grade inflammatory activity in patients of ileocolonic CD and may be better suited than conventional MRE for monitoring the activity of CD.

Entities:  

Mesh:

Year:  2017        PMID: 28079618     DOI: 10.1097/MIB.0000000000001001

Source DB:  PubMed          Journal:  Inflamm Bowel Dis        ISSN: 1078-0998            Impact factor:   5.325


  10 in total

1.  Potential of diffusion-weighted imaging in magnetic resonance enterography to identify neoplasms in the ileocecal region: Use of ultra-high b-value diffusion-weighted imaging.

Authors:  Hao Yu; Cui Feng; Zi Wang; Jianjun Li; Yanchun Wang; Xuemei Hu; Zhen Li; Yaqi Shen; Daoyu Hu
Journal:  Oncol Lett       Date:  2019-06-05       Impact factor: 2.967

2.  Preoperative evaluation of small bowel complications in Crohn's disease: comparison of diffusion-weighted and contrast-enhanced MR imaging.

Authors:  M Barat; C Hoeffel; M Bouquot; A S Jannot; R Dautry; M Boudiaf; K Pautrat; R Kaci; M Camus; C Eveno; M Pocard; P Soyer; A Dohan
Journal:  Eur Radiol       Date:  2018-10-09       Impact factor: 5.315

3.  Ability of DWI to characterize bowel fibrosis depends on the degree of bowel inflammation.

Authors:  Xue-Hua Li; Ren Mao; Si-Yun Huang; Zhuang-Nian Fang; Bao-Lan Lu; Jin-Jiang Lin; Shan-Shan Xiong; Min-Hu Chen; Zi-Ping Li; Can-Hui Sun; Shi-Ting Feng
Journal:  Eur Radiol       Date:  2019-01-11       Impact factor: 5.315

4.  IVIM with fractional perfusion as a novel biomarker for detecting and grading intestinal fibrosis in Crohn's disease.

Authors:  Meng-Chen Zhang; Xue-Hua Li; Si-Yun Huang; Ren Mao; Zhuang-Nian Fang; Qing-Hua Cao; Zhong-Wei Zhang; Xu Yan; Min-Hu Chen; Zi-Ping Li; Can-Hui Sun; Shi-Ting Feng
Journal:  Eur Radiol       Date:  2018-12-13       Impact factor: 5.315

5.  Avoiding contrast-enhanced sequences does not compromise the precision of the simplified MaRIA for the assessment of non-penetrating Crohn's disease activity.

Authors:  Agnès Fernàndez-Clotet; Víctor Sapena; Nunzia Capozzi; Sonia Rodríguez; Maria-Carme Masamunt; Elena Ricart; Ingrid Ordás; Julian Panés; Jordi Rimola
Journal:  Eur Radiol       Date:  2022-01-15       Impact factor: 5.315

6.  Apparent diffusion coefficient for assessing Crohn's disease activity: a meta-analysis.

Authors:  Maximilian Thormann; Bohdan Melekh; Caroline Bär; Maciej Pech; Jazan Omari; Andreas Wienke; Hans-Jonas Meyer; Alexey Surov
Journal:  Eur Radiol       Date:  2022-09-28       Impact factor: 7.034

7.  A Systematic Review of Technical Parameters for MR of the Small Bowel in non-IBD Conditions over the Last Ten Years.

Authors:  Jingyu Lu; Ziling Zhou; John N Morelli; Hao Yu; Yan Luo; Xuemei Hu; Zhen Li; Daoyu Hu; Yaqi Shen
Journal:  Sci Rep       Date:  2019-10-01       Impact factor: 4.379

8.  Computed Tomography Enterography: Quantitative Evaluation on Crohn's Disease Activity.

Authors:  Jingyun Cheng; Hui Xie; Hao Yang; Ke Wang; Guobin Xu; Guangyao Wu
Journal:  Gastroenterol Res Pract       Date:  2018-07-22       Impact factor: 2.260

9.  Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn's Disease?

Authors:  Levent Soydan; Ali Aslan Demir; Serhat Ozer; Selvinaz Ozkara
Journal:  J Belg Soc Radiol       Date:  2019-01-18       Impact factor: 1.894

10.  Comparison of Three Magnetization Transfer Ratio Parameters for Assessment of Intestinal Fibrosis in Patients with Crohn's Disease.

Authors:  Jixin Meng; Siyun Huang; CanHui Sun; Zhong Wei Zhang; Ren Mao; Yan Hong Yang; Shi Ting Feng; Zi Ping Li; XueHua Li
Journal:  Korean J Radiol       Date:  2020-03       Impact factor: 3.500

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.