Zhi-Peng Zhou1, Li-Ling Long1, Li-Juan Huang1, Teng-Fei Yang1, Zhong-Kui Huang2. 1. Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, Guangxi, People's Republic of China. 2. Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, Guangxi, People's Republic of China. huangzhk1205@sina.com.
Abstract
OBJECTIVES: To compare hepatobiliary phase (HBP) images obtained at 10 and 20 min after Gd-EOB-DTPA-enhanced MRI for assessment of liver function in rabbit fibrosis model on 3.0 T MR imaging. METHODS: 34 animals were separated into three groups: 5 for a control group, 14 for a mild fibrosis group, and 15 for a severe fibrosis group based on pathological proof. T1 relaxation times (T1rt) were measured on T1 mapping and reduction rates of T1rt (rrT1rt) were calculated. HBP images were obtained at 10 and 20 min after Gd-EOB-DTPA enhancement. Indocyanine green retention rates at 15 min (ICG R15) were performed for all animals. RESULTS: T1rt on pre-enhancement imaging showed no significant difference (p > 0.05) among all groups. T1rt on 10 min HBP and 20 min HBP showed significant difference (p < 0.05) among all groups. T1rt and rrT1rt in three groups showed no-significant difference (p > 0.05) between 10 min HBP and 20 min HBP. T1rt on both 10 and 20 min HBP showed significant correlation with ICG R15 (p < 0.05); rrT1rt on both 10 min HBP and 20 min HBP showed significant inverse correlation with ICG R15 (p < 0.05). CONCLUSIONS: Comparing 10 min HBP and 20 min HBP T1 mapping after Gd-EOB-DTPA enhancement, our results suggest that 10 min HBP T1 mapping is feasible for quantitatively assessing liver function.
OBJECTIVES: To compare hepatobiliary phase (HBP) images obtained at 10 and 20 min after Gd-EOB-DTPA-enhanced MRI for assessment of liver function in rabbitfibrosis model on 3.0 T MR imaging. METHODS: 34 animals were separated into three groups: 5 for a control group, 14 for a mild fibrosis group, and 15 for a severe fibrosis group based on pathological proof. T1 relaxation times (T1rt) were measured on T1 mapping and reduction rates of T1rt (rrT1rt) were calculated. HBP images were obtained at 10 and 20 min after Gd-EOB-DTPA enhancement. Indocyanine green retention rates at 15 min (ICG R15) were performed for all animals. RESULTS: T1rt on pre-enhancement imaging showed no significant difference (p > 0.05) among all groups. T1rt on 10 min HBP and 20 min HBP showed significant difference (p < 0.05) among all groups. T1rt and rrT1rt in three groups showed no-significant difference (p > 0.05) between 10 min HBP and 20 min HBP. T1rt on both 10 and 20 min HBP showed significant correlation with ICG R15 (p < 0.05); rrT1rt on both 10 min HBP and 20 min HBP showed significant inverse correlation with ICG R15 (p < 0.05). CONCLUSIONS: Comparing 10 min HBP and 20 min HBP T1 mapping after Gd-EOB-DTPA enhancement, our results suggest that 10 min HBP T1 mapping is feasible for quantitatively assessing liver function.
Authors: T Kim; T Murakami; Y Hasuike; M Gotoh; N Kato; M Takahashi; T Miyazawa; Y Narumi; M Monden; H Nakamura Journal: J Magn Reson Imaging Date: 1997 Jul-Aug Impact factor: 4.813
Authors: J E van Montfoort; B Stieger; D K Meijer; H J Weinmann; P J Meier; K E Fattinger Journal: J Pharmacol Exp Ther Date: 1999-07 Impact factor: 4.030
Authors: Jinhong Jung; Sang Min Yoon; Byungchul Cho; Young Eun Choi; Jungwon Kwak; So Yeon Kim; Sang-Wook Lee; Seung Do Ahn; Eun Kyung Choi; Jong Hoon Kim Journal: J Med Imaging Radiat Oncol Date: 2015-10-27 Impact factor: 1.735