Literature DB >> 28063273

Mechanisms of compensation in the gait of patients with drop foot.

Michalina Błażkiewicz1, Ida Wiszomirska2, Katarzyna Kaczmarczyk2, Grażyna Brzuszkiewicz-Kuźmicka2, Andrzej Wit2.   

Abstract

BACKGROUND: Drop foot is a complex syndrome, with multiple interactions between joints and muscles. Abnormalities in movement patterns can be measured using motion capture techniques, but identifying compensation mechanisms remains challenging.
METHODS: In order to identify compensatory mechanisms in patients with drop foot, this study evaluated a sample of 15 such patients using a computerized gait analysis system, as compared to a group of 15 healthy subjects.
FINDINGS: Four classes of parameters were distinguished, falling in differing intervals of percentage differences between the groups in the study. The first class comprised two kinematic parameters for which the values of percentage differences in the control group were more than 100% greater than for the patient group. The second class comprised two kinetic parameters falling in the interval of 100-49%. In the third class, in the 49-20% interval the main differences were observed for spatiotemporal parameters, whereas in the 20-4% interval the differences were distributed similarly for kinematic, kinetic and spatiotemporal parameters.
INTERPRETATION: These differences in gait pattern between the groups may be related to both primary motor deficits and secondary compensatory mechanisms. Generally, we conclude that drop foot affects the patients' overall kinematic and kinetic gait parameters, with compensation seen as a chain originating from a change of movement within the ankle joint.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Compensation; Drop foot; Gait

Mesh:

Year:  2017        PMID: 28063273     DOI: 10.1016/j.clinbiomech.2016.12.014

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  3 in total

1.  A foot drop compensation device based on surface multi-field functional electrical stimulation-Usability study in a clinical environment.

Authors:  Eukene Imatz-Ojanguren; Gema Sánchez-Márquez; Jose Ramón Asiain-Aristu; Joxean Cueto-Mendo; Edurne Jaunarena-Goicoechea; Haritz Zabaleta; Thierry Keller
Journal:  J Rehabil Assist Technol Eng       Date:  2019-09-03

2.  Individualized feedback to change multiple gait deficits in chronic stroke.

Authors:  Kevin A Day; Kendra M Cherry-Allen; Amy J Bastian
Journal:  J Neuroeng Rehabil       Date:  2019-12-23       Impact factor: 5.208

3.  The comparison of the effect of innovative designed storing-restoring hybrid passive AFO versus posterior leaf spring AFO on ankle joint kinematic in drop foot patients: A case series using a single subject design.

Authors:  Ensieh Pourhoseingholi; Mohammad Kamali; Hassan Saeedi; Maryam Jalali
Journal:  Med J Islam Repub Iran       Date:  2020-12-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.