Literature DB >> 2806229

The accuracy of the critical power test for predicting time to exhaustion during cycle ergometry.

D J Housh, T J Housh, S M Bauge.   

Abstract

The purpose of this study was to determine the relationship between actual time to exhaustion or time limit (ATLIM) during bicycle ergometry and predicted time to exhaustion (PTLIM) from the Critical Power (CP) test. fourteen males (means +/- SD = 22.36 +/- 2.13 years) volunteered as subjects for this investigation. The subjects visited the laboratory on seven occasions separated by at least 24 h. The first two visits were used for the determination of CP; during the remaining sessions the subjects rode a Monarch bicycle ergometer at power loadings of CP - 20%, CP, CP + 20%, CP + 40% and CP + 60% for the determination of ATLIM. Theoretically, power loadings less than or equal to CP can be maintained indefinitely without exhaustion and the PTLIM for power loadings greater than CP can be estimated from the results of the CP test. The accuracy of the CP test for estimating the time to exhaustion during bicycle ergometry was determined by comparing ATLIM to PTLIM using correlation coefficients, standard error of estimates and related t-tests. The results of this study indicated that there were no significant (p greater than 0.05) differences between ATLIM and PTLIM for power loadings greater than CP (ATLIM vs PTLIM at CP + 20% = 8.19 +/- 3.90 vs 7.13 +/- 2.69 min, t = 2.106, r = 0.893, SEE = 1.21 min; CP + 40% = 3.60 +/- 1.37 vs 3.46 +/- 1.18 min, t = 0.842, r = 0.882, SEE = 0.556 min; CP + 60% = 2.36 +/- 0.95 vs 2.32 +/- 0.79 min; t = 0.328 r = 0.841, SEE = 0.428 min).(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1989        PMID: 2806229     DOI: 10.1080/00140138908966860

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  23 in total

1.  VO2 slow component and performance in endurance sports.

Authors:  V L Billat
Journal:  Br J Sports Med       Date:  2000-04       Impact factor: 13.800

Review 2.  Methods to determine aerobic endurance.

Authors:  Laurent Bosquet; Luc Léger; Patrick Legros
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

3.  Maximal lactate steady state, respiratory compensation threshold and critical power.

Authors:  J Dekerle; B Baron; L Dupont; J Vanvelcenaher; P Pelayo
Journal:  Eur J Appl Physiol       Date:  2003-03-04       Impact factor: 3.078

4.  Physiological responses of young and elderly men to prolonged exercise at critical power.

Authors:  T J Overend; D A Cunningham; D H Paterson; W D Smith
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1992

5.  Physiological responses at five estimates of critical velocity.

Authors:  Anthony J Bull; Terry J Housh; Glen O Johnson; Sharon R Rana
Journal:  Eur J Appl Physiol       Date:  2007-12-19       Impact factor: 3.078

6.  Assessment of short-distance breaststroke swimming performance with critical velocity.

Authors:  Daijiro Abe; Hiroaki Tokumaru; Shigemitsu Niihata; Satoshi Muraki; Yoshiyuki Fukuoka; Sachio Usui; Takayoshi Yoshida
Journal:  J Sports Sci Med       Date:  2006-06-01       Impact factor: 2.988

7.  Blood lactate in trained cyclists during cycle ergometry at critical power.

Authors:  D G Jenkins; B M Quigley
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

Review 8.  The relationship between power output and endurance: a brief review.

Authors:  R H Morton; D J Hodgson
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

9.  Fast-start strategy increases the time spent above 95 %VO2max during severe-intensity intermittent running exercise.

Authors:  Rafael Alves de Aguiar; Tiago Turnes; Rogério Santos de Oliveira Cruz; Fabrizio Caputo
Journal:  Eur J Appl Physiol       Date:  2012-10-02       Impact factor: 3.078

Review 10.  The critical power concept. A review.

Authors:  D W Hill
Journal:  Sports Med       Date:  1993-10       Impact factor: 11.136

View more