Literature DB >> 28056711

Optimization of custom cementless stem using finite element analysis and elastic modulus distribution for reducing stress-shielding effect.

Gurunathan Saravana Kumar1, Subin Philip George2.   

Abstract

This work proposes a methodology involving stiffness optimization for subject-specific cementless hip implant design based on finite element analysis for reducing stress-shielding effect. To assess the change in the stress-strain state of the femur and the resulting stress-shielding effect due to insertion of the implant, a finite element analysis of the resected femur with implant assembly is carried out for a clinically relevant loading condition. Selecting the von Mises stress as the criterion for discriminating regions for elastic modulus difference, a stiffness minimization method was employed by varying the elastic modulus distribution in custom implant stem. The stiffness minimization problem is formulated as material distribution problem without explicitly penalizing partial volume elements. This formulation enables designs that could be fabricated using additive manufacturing to make porous implant with varying levels of porosity. Stress-shielding effect, measured as difference between the von Mises stress in the intact and implanted femur, decreased as the elastic modulus distribution is optimized.

Entities:  

Keywords:  Stress shielding; cementless hip implant; custom implant; elastic modulus distribution; femur; finite element analysis; optimization

Mesh:

Year:  2017        PMID: 28056711     DOI: 10.1177/0954411916686125

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Enhanced Bone Remodeling Effects of Low-Modulus Ti-5Zr-3Sn-5Mo-25Nb Alloy Implanted in the Mandible of Beagle Dogs under Delayed Loading.

Authors:  Jing Hu; Xiaobo Zhong; Xiaoming Fu
Journal:  ACS Omega       Date:  2019-11-01

2.  Mechanobiologically optimized Ti-35Nb-2Ta-3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy.

Authors:  Chuanyuan Mao; Weijun Yu; Min Jin; Yingchen Wang; Xiaoqing Shang; Lu Lin; Xiaoqin Zeng; Liqiang Wang; Eryi Lu
Journal:  Bioact Mater       Date:  2022-03-16

3.  Two Different Strategies to Enhance Osseointegration in Porous Titanium: Inorganic Thermo-Chemical Treatment Versus Organic Coating by Peptide Adsorption.

Authors:  Monica Ortiz-Hernandez; Katrin S Rappe; Meritxell Molmeneu; Carles Mas-Moruno; Jordi Guillem-Marti; Miquel Punset; Cristina Caparros; Jose Calero; Jordi Franch; Mariano Fernandez-Fairen; Javier Gil
Journal:  Int J Mol Sci       Date:  2018-08-30       Impact factor: 5.923

4.  Stress analysis in a bone fracture fixed with topology-optimised plates.

Authors:  Abdulsalam Abdulaziz Al-Tamimi; Carlos Quental; Joao Folgado; Chris Peach; Paulo Bartolo
Journal:  Biomech Model Mechanobiol       Date:  2019-10-24
  4 in total