Literature DB >> 2805480

A comparative study of the initial stability of cementless hip prostheses.

E Schneider1, C Kinast, J Eulenberger, D Wyder, G Eskilsson, S M Perren.   

Abstract

In the process of prosthetic loosening, the initial motion of the implant relative to the bone is a key element. In order to provide quantitative information, three straight and one curved cementless hip stems were submitted to in vitro tests in autopsy specimens of the femur under dynamic axial and torsional loads with the displacements measured in several directions. The results were compared to those of an additional group of cemented straight stem prostheses providing reference values. Subsidence of cementless implants on the average was significantly higher than the cemented reference, but single implants were comparable to the reference. Rotational motion was distinctly higher than the reference values, with considerable differences between designs. When comparing displacements perpendicular to the main load direction, the sagittal plane motion was found to be at least double the motion in the frontal plane. Micromotions at the prosthesis/bone interfaces under the load case selected were smallest for the curved and highest for one of the straight prostheses.

Mesh:

Substances:

Year:  1989        PMID: 2805480

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

Review 1.  New Developments of Ti-Based Alloys for Biomedical Applications.

Authors:  Yuhua Li; Chao Yang; Haidong Zhao; Shengguan Qu; Xiaoqiang Li; Yuanyuan Li
Journal:  Materials (Basel)       Date:  2014-03-04       Impact factor: 3.623

2.  Fabrication of porous-Ti6Al4V alloy by using hot pressing technique and Mg space holder for hard-tissue biomedical applications.

Authors:  N Aslan; B Aksakal; F Findik
Journal:  J Mater Sci Mater Med       Date:  2021-06-30       Impact factor: 3.896

3.  The influence of stem length and fixation on initial femoral component stability in revision total knee replacement.

Authors:  N Conlisk; H Gray; P Pankaj; C R Howie
Journal:  Bone Joint Res       Date:  2012-11-01       Impact factor: 5.853

4.  The Effects of Interlocking a Universal Hip Cementless Stem on Implant Subsidence and Mechanical Properties of Cadaveric Canine Femora.

Authors:  Yonathan Buks; Kirk L Wendelburg; Susan M Stover; Tanya C Garcia-Nolen
Journal:  Vet Surg       Date:  2016-01-15       Impact factor: 1.495

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.