Literature DB >> 28050692

Effect of inversion time on the precision of myocardial late gadolinium enhancement quantification evaluated with synthetic inversion recovery MR imaging.

Akos Varga-Szemes1, Rob J van der Geest2, U Joseph Schoepf3, Bruce S Spottiswoode4, Carlo N De Cecco1, Giuseppe Muscogiuri1,5, Julian L Wichmann1,6, Stefanie Mangold1,7, Stephen R Fuller1, Pal Maurovich-Horvat8, Bela Merkely8, Sheldon E Litwin9, Rozemarijn Vliegenthart1,10, Pal Suranyi1.   

Abstract

OBJECTIVES: To evaluate the influence of inversion time (TI) on the precision of myocardial late gadolinium enhancement (LGE) quantification using synthetic inversion recovery (IR) imaging in patients with myocardial infarction (MI).
METHODS: Fifty-three patients with suspected prior MI underwent 1.5-T cardiac MRI with conventional magnitude (MagIR) and phase-sensitive IR (PSIR) LGE imaging and T1 mapping at 15 min post-contrast. T1-based synthetic MagIR and PSIR images were calculated with a TI ranging from -100 to +150 ms at 5-ms intervals relative to the optimal TI (TI0). LGE was quantified using a five standard deviation (5SD) and full width at half-maximum (FWHM) thresholds. Measurements were compared using one-way analysis of variance.
RESULTS: The MagIRsy technique provided precise assessment of LGE area at TIs ≥ TI0, while precision was decreased below TI0. The LGE area showed significant differences at ≤ -25 ms compared to TI0 using 5SD (P < 0.001) and at ≤ -65 ms using the FWHM approach (P < 0.001). LGE measurements did not show significant difference over the analysed TI range in the PSIRsy images using either of the quantification methods.
CONCLUSIONS: T1 map-based PSIRsy images provide precise quantification of MI independent of TI at the investigated time point post-contrast. MagIRsy-based MI quantification is precise at TI0 and at longer TIs while showing decreased precision at TI values below TI0. KEY POINTS: • Synthetic IR imaging retrospectively generates LGE images at any theoretical TI • Synthetic IR imaging can simulate the effect of TI on LGE quantification • Fifteen minutes post-contrast MagIR sy accurately quantifies infarcts from TI 0 to TI 0   + 150 ms • Fifteen minutes post-contrast PSIR sy provides precise infarct size independent of TI • Synthetic IR imaging has further advantages in reducing operator dependence.

Entities:  

Keywords:  Cardiovascular magnetic resonance; Late gadolinium enhancement; Myocardial infarct; Synthetic inversion recovery; T1 mapping

Mesh:

Substances:

Year:  2017        PMID: 28050692     DOI: 10.1007/s00330-016-4665-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  An improved MR imaging technique for the visualization of myocardial infarction.

Authors:  O P Simonetti; R J Kim; D S Fieno; H B Hillenbrand; E Wu; J M Bundy; J P Finn; R M Judd
Journal:  Radiology       Date:  2001-01       Impact factor: 11.105

2.  Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting.

Authors:  Hui Xue; Andreas Greiser; Sven Zuehlsdorff; Marie-Pierre Jolly; Jens Guehring; Andrew E Arai; Peter Kellman
Journal:  Magn Reson Med       Date:  2012-06-26       Impact factor: 4.668

3.  Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

Authors:  Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

4.  Age-independent myocardial infarct quantification by signal intensity percent infarct mapping in swine.

Authors:  Zsofia Lenkey; Akos Varga-Szemes; Tamas Simor; Rob J van der Geest; Robert Kirschner; Levente Toth; Tamas Bodnar; Brigitta C Brott; Ada Elgavish; Gabriel A Elgavish
Journal:  J Magn Reson Imaging       Date:  2015-09-10       Impact factor: 4.813

5.  Infarct density distribution by MRI in the porcine model of acute and chronic myocardial infarction as a potential method transferable to the clinic.

Authors:  Akos Varga-Szemes; Tamas Simor; Zsofia Lenkey; Rob J van der Geest; Robert Kirschner; Levente Toth; Brigitta C Brott; Ada Elgavish; Gabriel A Elgavish
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-10       Impact factor: 2.357

6.  Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement.

Authors:  Peter Kellman; Andrew E Arai; Elliot R McVeigh; Anthony H Aletras
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

7.  Effects of time, dose, and inversion time for acute myocardial infarct size measurements based on magnetic resonance imaging-delayed contrast enhancement.

Authors:  Anja Wagner; Heiko Mahrholdt; Louise Thomson; Stefan Hager; Gabriel Meinhardt; Wolfgang Rehwald; Michele Parker; Dipan Shah; Udo Sechtem; Raymond J Kim; Robert M Judd
Journal:  J Am Coll Cardiol       Date:  2006-04-27       Impact factor: 24.094

8.  Myocardial Late Gadolinium Enhancement: Accuracy of T1 Mapping-based Synthetic Inversion-Recovery Imaging.

Authors:  Akos Varga-Szemes; Rob J van der Geest; Bruce S Spottiswoode; Pal Suranyi; Balazs Ruzsics; Carlo N De Cecco; Giuseppe Muscogiuri; Paola M Cannaò; Mary A Fox; Julian L Wichmann; Rozemarijn Vliegenthart; U Joseph Schoepf
Journal:  Radiology       Date:  2015-07-30       Impact factor: 11.105

9.  Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold.

Authors:  Stefan K Piechnik; Vanessa M Ferreira; Erica Dall'Armellina; Lowri E Cochlin; Andreas Greiser; Stefan Neubauer; Matthew D Robson
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-19       Impact factor: 5.364

10.  Quantification of late gadolinium enhanced CMR in viability assessment in chronic ischemic heart disease: a comparison to functional outcome.

Authors:  Aernout M Beek; Olga Bondarenko; Farshid Afsharzada; Albert C van Rossum
Journal:  J Cardiovasc Magn Reson       Date:  2009-03-09       Impact factor: 5.364

View more
  5 in total

1.  Quantitative inversion time prescription for myocardial late gadolinium enhancement using T1-mapping-based synthetic inversion recovery imaging: reducing subjectivity in the estimation of inversion time.

Authors:  Sebastian Gassenmaier; Rob J van der Geest; U Joseph Schoepf; Pal Suranyi; Wolfgang G Rehwald; Carlo N De Cecco; Domenico Mastrodicasa; Moritz H Albrecht; Domenico De Santis; Virginia W Lesslie; Balazs Ruzsics; Akos Varga-Szemes
Journal:  Int J Cardiovasc Imaging       Date:  2018-01-05       Impact factor: 2.357

2.  Functional LGE Imaging: Cardiac Phase-Resolved Assessment of Focal Fibrosis.

Authors:  Sebastian Weingartner; Omer Burak Demirel; Chetan Shenoy; Lothar R Schad; Jeanette Schulz-Menger; Mehmet Akcakaya
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

3.  The image quality and diagnostic accuracy of T1-mapping-based synthetic late gadolinium enhancement imaging: comparison with conventional late gadolinium enhancement imaging in real-life clinical situation.

Authors:  Suji Lee; Panki Kim; Dong Jin Im; Young Joo Suh; Yoo Jin Hong; Byoung Wook Choi; Young Jin Kim
Journal:  J Cardiovasc Magn Reson       Date:  2022-04-14       Impact factor: 6.903

4.  Cardiac phase-resolved late gadolinium enhancement imaging.

Authors:  Sebastian Weingärtner; Ömer B Demirel; Francisco Gama; Iain Pierce; Thomas A Treibel; Jeanette Schulz-Menger; Mehmet Akçakaya
Journal:  Front Cardiovasc Med       Date:  2022-09-29

5.  Accurate late gadolinium enhancement prediction by early T1- based quantitative synthetic mapping.

Authors:  Randy van Dijk; Dirkjan Kuijpers; Theodorus A M Kaandorp; Paul R M van Dijkman; Rozemarijn Vliegenthart; Pim van der Harst; Matthijs Oudkerk
Journal:  Eur Radiol       Date:  2017-08-30       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.