Literature DB >> 28043711

Total Hip Arthroplasty With a Fully Hydroxyapatite-Coated Stem: A Cohort Study During 23-28 Years.

Olav Reikerås1.   

Abstract

BACKGROUND: Long-term results of a hydroxyapatite (HA)-coated stem are sparse. We have followed a cohort of patients operated with a grit-blasted titanium stem designed for press-fit insertion and entirely plasma-sprayed with HA up to 28 years.
METHODS: In the years 1988-1993, we performed 323 primary total hip arthroplasties in 276 patients (189 women). Their mean age was 48 (15-79) years. During the following years, 83 patients with 88 hips have died, and 18 patients did not attend the follow-up examination, but had no major symptoms according to telephone interviews and control examination. Thus, 212 patients (255 hips) were followed up for more than 20 years.
RESULTS: Three patients were revised because of late periprosthetic infection, 1 because of a fall with periprosthetic fracture, and 2 stems were revised due to mechanical failure. Osteolysis was significantly associated with wear, and wear was significantly associated with the size of the femoral head. We found a small amount of proximal bone loss and a low incidence of distal hypertrophy of the bone. The bone changes confirmed a well-fixed femoral component in asymptomatic patients.
CONCLUSION: Our findings indicate an essentially physiological weight distribution from the stem to the femoral bone with no significant thigh pain. The changes in the bone confirmed that the femoral component was well-fixed, and we conclude that a fully HA-coated titanium stem designed for press-fit insertion lasts for 23-28 years.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  arthroplasty; hip; hydroxyapatite; revision; stem

Mesh:

Substances:

Year:  2016        PMID: 28043711     DOI: 10.1016/j.arth.2016.12.008

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis.

Authors:  Yohei Ohyama; Yukihide Minoda; Yoichi Ohta; Ryo Sugama; Susumu Takemura; Hiroaki Nakamura
Journal:  Arch Orthop Trauma Surg       Date:  2022-10-19       Impact factor: 2.928

2.  Subtrochanteric shortening and uncemented arthroplasty in hips with high dislocation - a cohort study with 13-30 years follow-up.

Authors:  Anne Guro Vreim Holm; Terje Terjesen; Olav Reikerås
Journal:  J Orthop       Date:  2018-12-20

3.  Occult periprosthetic femoral fractures occur frequently during a long, trapezoidal, double-tapered cementless femoral stem fixation in primary THA.

Authors:  Ho Hyun Yun; Jung Taek Lim; Se-Hyun Yang; Phil Sun Park
Journal:  PLoS One       Date:  2019-09-19       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.