Literature DB >> 28042113

Not all cementless femoral stems are created equal but the results may be comparable.

S W Carlson1, S S Liu1, J J Callaghan1.   

Abstract

AIMS: The aim of this study was to compare the survivorship and radiographic outcomes at ten-year follow-up of three prospective consecutive series of patients each of which received a different design of cementless femoral components for total hip arthroplasty (THA). PATIENTS AND METHODS: In Cohort 1, 91 consecutive patients (100 hips) underwent THA with a cementless porous-coated anatomic femoral stem (PCA) between October 1983 and January 1986. In Cohort 2, 86 consecutive patients (100 hips) underwent THA with an extensively porous-coated cementless femoral stem (Prodigy) between June 1994 and October 1997. In Cohort 3, 88 consecutive patients (100 hips) underwent THA with a proximally porous-coated triple-tapered cementless stem (Summit) between April 2002 and October 2003. All three groups underwent prospective clinical and radiographic evaluation.
RESULTS: Kaplan-Meier survivorship analysis of Cohort 1 was 91% (95% confidence interval (CI) 88 to 94) with an endpoint of revision for any reason and 97% (95% CI 95 to 99) with aseptic loosening as the endpoint. Survivorship of Cohort 2 was 88% (95% CI 79 to 97) for revision for any reason and 100% for aseptic loosening. Survivorship of Cohort 3 was 95% (95% CI 91 to 99) for revision for any reason and 100% with aseptic loosening as the endpoint.
CONCLUSION: With revision for aseptic loosening of the femoral component as the endpoint, the three femoral components with different design philosophies demonstrated excellent survivorship, ranging from 97% to 100% at ten years. Cite this article: Bone Joint J 2017;99-B(1 Supple A):14-17. ©2017 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Cementless total hip arthroplasty; Primary total hip arthroplasty; Prosthesis design

Mesh:

Substances:

Year:  2017        PMID: 28042113     DOI: 10.1302/0301-620X.99B1.BJJ-2016-0269.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  2 in total

Review 1.  The current role of robotics in total hip arthroplasty.

Authors:  Babar Kayani; Sujith Konan; Atif Ayuob; Salamah Ayyad; Fares S Haddad
Journal:  EFORT Open Rev       Date:  2019-11-01

2.  Long-term outcomes of a dual-mobility cup and cementless triple-taper femoral stem combination in total hip replacement: a multicenter retrospective analysis.

Authors:  Alain Cypres; Arnaud Fiquet; Philippe Girardin; David Fitch; Philippe Bauchu; Olivier Bonnard; Daniel Noyer; Christophe Roy
Journal:  J Orthop Surg Res       Date:  2019-11-21       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.