Literature DB >> 2804176

Pulsed Doppler measurement of left ventricular output as early predictor of symptomatic patent ductus arteriosus in very preterm infants.

F J Walther1, D H Kim, M Ebrahimi, B Siassi.   

Abstract

High left ventricular output (LVO) values are associated with symptomatic left-to-right ductal shunting in preterm infants. However, LVO data prior to the occurrence of symptomatic patent ductus arteriosus (SPDA) are lacking. To determine whether serial measurements could predict a SPDA, we measured LVO from day 1 until day 10 with pulsed Doppler echocardiography in 25 preterm infants with birth weights of less than 1,250 g and hematocrits of more than 0.40. Eleven infants never developed patent ductus arteriosus symptoms and had LVO values within the normal range (190-310 ml/min/kg) with only minimal daily variations. The remaining 14 infants developed SPDA which required treatment with indomethacin, ductal ligation, or fluid restriction on days 2-5. From day 1 until day 5 their mean LVO values were significantly higher compared to the group without left-to-right ductal shunt and this increase was secondary to higher stroke volume values. An increase in LVO of more than 60 ml/min/kg consistently preceded SPDA by at least 24 h. Serial measurements of LVO using a single-pulsed Doppler approach can be used for early prediction of SPDA.

Entities:  

Mesh:

Year:  1989        PMID: 2804176     DOI: 10.1159/000243112

Source DB:  PubMed          Journal:  Biol Neonate        ISSN: 0006-3126


  16 in total

1.  Coronary blood flow in healthy neonates: effects of left ventricular function and mass.

Authors:  G Oskarsson; E Pesonen
Journal:  Pediatr Cardiol       Date:  2003-07-29       Impact factor: 1.655

2.  Diagnosis and Management of Patent Ductus Arteriosus.

Authors:  Maria Gillam-Krakauer; Jeff Reese
Journal:  Neoreviews       Date:  2018-07

3.  Severity of the ductal shunt: a comparison of different markers.

Authors:  M El Hajjar; G Vaksmann; T Rakza; G Kongolo; L Storme
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-09       Impact factor: 5.747

Review 4.  Does echocardiography facilitate determination of hemodynamic significance attributable to the ductus arteriosus?

Authors:  Arvind Sehgal; Patrick J McNamara
Journal:  Eur J Pediatr       Date:  2009-04-22       Impact factor: 3.183

5.  Early determinants of right and left ventricular output in ventilated preterm infants.

Authors:  N Evans; M Kluckow
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-03       Impact factor: 5.747

6.  A Preterm Physiologically Based Pharmacokinetic Model. Part I: Physiological Parameters and Model Building.

Authors:  Khaled Abduljalil; Xian Pan; Amita Pansari; Masoud Jamei; Trevor N Johnson
Journal:  Clin Pharmacokinet       Date:  2020-04       Impact factor: 6.447

Review 7.  Diagnosis of patent ductus arteriosus in the preterm newborn.

Authors:  N Evans
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

8.  Patent ductus arteriosus in the newborn.

Authors:  G Hartnoll; P Betremieux; N Modi
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-05       Impact factor: 5.747

9.  Change in blood pressure after treatment of patent ductus arteriosus with indomethacin.

Authors:  N Evans; P Iyer
Journal:  Arch Dis Child       Date:  1993-05       Impact factor: 3.791

10.  Longitudinal changes in the diameter of the ductus arteriosus in ventilated preterm infants: correlation with respiratory outcomes.

Authors:  N Evans; P Iyer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-05       Impact factor: 5.747

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.