Literature DB >> 28040758

Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

Enrico Ferrari1, Giorgio Franciosi1, Sara Clivio2, Francesco Faletra3, Marco Moccetti3, Tiziano Moccetti3, Giovanni Pedrazzini3, Stefanos Demertzis1.   

Abstract

Objectives: The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch.
Methods: Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery.
Results: Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Conclusions: Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery.
© The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic valve replacement; Patient–prosthesis mismatch; Redo cardiac surgery; Transcatheter aortic valve replacement

Mesh:

Year:  2017        PMID: 28040758     DOI: 10.1093/icvts/ivw397

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  1 in total

1.  The use of balloon-expandable Sapien-3 valve in redo aortic valve replacement and the potential risk of left main stem occlusion.

Authors:  Thomas Theologou; Sara Clivio; Adel Younes; Stefanos Demertzis; Enrico Ferrari
Journal:  J Card Surg       Date:  2022-03-31       Impact factor: 1.778

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.