In-vitro investigation of the hemodynamic responses of the cerebral, coronary and renal circulations with a rotary blood pump installed in the descending aorta.

M A Rezaienia1, G Paul1, E J Avital1, S Mozafari1, M Rothman2, T Korakianitis3.   

Abstract

This study investigates the hemodynamic responses of the cardiovascular system when a rotary blood pump is operating in the descending aorta, with a focus on the cerebral, coronary and renal autoregulation, using our in-house cardiovascular emulator. Several improvements have been made from our previous studies. A novel coronary system was developed to replicate the native coronary perfusion. Three pinch valves actuated by stepper motors were used to simulate the regional autoregulation systems of the native cerebral, coronary and renal circulations. A rotary pump was installed in the descending aorta, in series with the heart, and the hemodynamic responses of the cardiovascular system were investigated with a focus on cerebral, coronary and renal circulation over a wide range of pump rotor speeds. Experiments were performed twice, once with the autoregulation systems active and once with the autoregulation systems inactive, to reflect that there will be some impairment of autoregulatory systems in a patient with heart failure. It was shown that by increasing the rotor speed to 3000 rpm, the cardiac output was improved from 2.9 to 4.1 L/min as a result of an afterload reduction induced by the pressure drop upstream of the pump. The magnitudes of changes in perfusion in the cerebral, coronary and renal circulations were recorded with regional autoregulation systems active and inactive.
Copyright © 2016. Published by Elsevier Ltd.

Entities:  

Keywords:  Blood pump; Cardiovascular simulator; MCS; RBP; VAD

Mesh:

Year:  2016        PMID: 28040435     DOI: 10.1016/j.medengphy.2016.11.006

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  2 in total

1.  Optimization of Axial Pump Characteristic Dimensions and Induced Hemolysis for Mechanical Circulatory Support Devices.

Authors:  Theodosios Korakianitis; Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Sahand Mozafari
Journal:  ASAIO J       Date:  2018 Nov/Dec       Impact factor: 2.872

2.  Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump.

Authors:  Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Theodosios Korakianitis
Journal:  ASAIO J       Date:  2018 Sep/Oct       Impact factor: 2.872

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.