Literature DB >> 2803855

Mechanical and morphological effects of strain rate on fatigue of compact bone.

M B Schaffler1, E L Radin, D B Burr.   

Abstract

Compact bone specimens were cyclically loaded in uniaxial tension for one million cycles; loading was performed at either of two physiological strain rates (0.01 s-1 or 0.03 s-1) and a physiological strain range (0-1200 microstrain). Microdamage in loaded and nonloaded control specimens was then assessed histomorphometrically. Fatigue, evidence by stiffness loss, was observed at both strain rates and was significantly greater in specimens loaded at the high experimental strain rate than in specimens loaded at the low strain rate. Morphologically, this fatigue corresponded to increased numbers of microcracks in the bone. These data show that fatigue and resultant microdamage are realistic expectations of cyclic loading within the physiological strain range. The rate at which strains are developed influences the fatigue behavior of compact bone, suggesting that cyclic loading at high physiological strain rates, characteristic of vigorous activities, is more damaging to compact bone than loading at lower physiological strain rates.

Entities:  

Mesh:

Year:  1989        PMID: 2803855     DOI: 10.1016/8756-3282(89)90055-0

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  51 in total

Review 1.  Microdamage and bone strength.

Authors:  David Burr
Journal:  Osteoporos Int       Date:  2003-08-29       Impact factor: 4.507

Review 2.  Biological aspects of early osteoarthritis.

Authors:  Henning Madry; Frank P Luyten; Andrea Facchini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-19       Impact factor: 4.342

3.  Microcracks and osteoclast resorption activity in vitro.

Authors:  Monika Rumpler; Tanja Würger; Paul Roschger; Elisabeth Zwettler; Herwig Peterlik; Peter Fratzl; Klaus Klaushofer
Journal:  Calcif Tissue Int       Date:  2012-01-24       Impact factor: 4.333

4.  Microcracks in compact bone: a three-dimensional view.

Authors:  S Mohsin; F J O'Brien; T C Lee
Journal:  J Anat       Date:  2006-07       Impact factor: 2.610

5.  Osteonal crack barriers in ovine compact bone.

Authors:  S Mohsin; F J O'Brien; T C Lee
Journal:  J Anat       Date:  2006-01       Impact factor: 2.610

6.  Bone microdamage.

Authors:  R D Chapurlat
Journal:  Osteoporos Int       Date:  2009-06       Impact factor: 4.507

Review 7.  Post-yield and failure properties of cortical bone.

Authors:  Uwe Wolfram; Jakob Schwiedrzik
Journal:  Bonekey Rep       Date:  2016-08-24

Review 8.  Bone microdamage: a clinical perspective.

Authors:  R D Chapurlat; P D Delmas
Journal:  Osteoporos Int       Date:  2009-03-17       Impact factor: 4.507

9.  Bisphosphonate-induced reductions in rat femoral bone energy absorption and toughness are testing rate-dependent.

Authors:  Eric R Smith; Matthew R Allen
Journal:  J Orthop Res       Date:  2013-03-13       Impact factor: 3.494

10.  Fluorescence-aided detection of microdamage in compact bone.

Authors:  T C Lee; E R Myers; W C Hayes
Journal:  J Anat       Date:  1998-08       Impact factor: 2.610

View more