Abstract

PURPOSE: Online tumor matching for SABR lung setup requires margins for inaccuracies due to intra-fraction variability of breathing-averaged tumor position (BATP) and CBCT image guidance. We studied intra-fraction variability during SABR delivery using VMAT, corrected these for measurement inaccuracies, and quantified the CBCT image-guidance uncertainties.
MATERIALS AND METHODS: For 193 fractions in 38 patients positioned without immobilization devices, CBCT scans were acquired before and after 2 arcs of a RapidArc treatment. A hidden marker test was performed to determine the accuracy of the CBCT system and an inter-observer test was performed to measure registration accuracy. Intra-fraction variability was calculated after correction for these components of variance, and the prediction interval for setup inaccuracies was determined.
RESULTS: Correction for measurement inaccuracies reduced the intra-fraction variability of the BATP from 1.9 to 1.6 mm in AP, from 1.7 to 1.4 mm in SI and from 1.5 to 1.1 mm in LR direction (1 SD). Intra-fraction variability in bony anatomy after correction was ≤ 1 mm (1 SD). The 95% prediction interval to account for CBCT image-guidance uncertainties and intra-fraction variability was determined, and was found to be within our institutional PTV margins of 5 mm.
CONCLUSIONS: Our findings show that it is essential to account for measurement and system inaccuracies when obtaining data for validating PTV margins from online CBCT image guidance.
© 2016 American Association of Physicists in Medicine.

Entities:  

Keywords:  SABR; SBRT; intra-fraction motion; lung cancer; setup errors

Mesh:

Year:  2017        PMID: 28032895     DOI: 10.1002/mp.12074

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Compare of Interfractional Setup Reproducibility Between Vacuum-Lock Bag and Thermoplastic Mask in Radiotherapy for Breast Cancer.

Authors:  Yaqi Song; Jin Peng; Qianfeng Chen; Honglei Luo
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec

2.  Psychosomatic symptoms affect radiotherapy setup errors in early breast cancer patients.

Authors:  Yi He; Chang Gao; Ying Pang; Jixiang Chen; Lili Tang
Journal:  Chin J Cancer Res       Date:  2021-06-30       Impact factor: 5.087

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.