Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system.

S Saksena1, N G Tullo, R B Krol, A M Mauro.   

Abstract

We evaluated the early clinical performance of an implantable cardioverter/defibrillator with a nonepicardial lead system in patients with refractory ventricular tachycardia or ventricular fibrillation. Ten patients, mean age 67 years, mean left ventricular ejection fraction 35%, refractory to 5 +/- 2 antiarrhythmic drugs and with a history of prior cardiac surgery (7 patients), severe lung disease (2 patients), or renal failure (1 patient) underwent device and lead system implant. A tripolar electrode catheter with one sensing electrode and two defibrillating electrodes was placed in the right ventricular apex and a left thoracic submuscular patch electrode was used in an epicostal location. Defibrillation energy threshold was determined using dual- or triple-electrode configurations. Optimal patch electrode location was determined after temporary use of a cutaneous patch electrode prior to cardioverter/defibrillator implant. Electrophysiologic studies were performed before discharge and after 2 to 3 months to assess device function. Percutaneous insertion and placement of the electrode catheter was achieved in all patients. Defibrillation energy threshold testing was done using 1 to 4 (mean, 2.7) electrode configurations per patient and required 6 to 21 (mean, 13) ventricular fibrillation inductions and 8 to 56 (mean, 22) shocks per patient. In all patients, lowest reliable defibrillation energy threshold was obtained with a triple-electrode configuration (right ventricular common cathode with right atrial and thoracic patch as dual anodes) and bidirectional shocks (mean, 18 +/- 5 J). Optimal patch electrode position could be determined in 9 of 10 patients, and these 9 patients had cardioverter/defibrillator implant. Ventricular fibrillation termination with the first delivered shock at electrophysiologic study was documented in all patients. There was no perioperative mortality in device-implanted patients. Postoperative electrophysiologic studies before discharge (9 patients) and at 3 months (8 patients) continued to demonstrate successful defibrillation by the first device shock. During follow-up (range, 2 to 10 months; mean, 6 +/- 3 months), spontaneous device discharges occurred in 4 patients with inappropriate shocks due to electrode catheter fracture being documented in 1 patient. Antiarrhythmic drug therapy was withdrawn in 6 patients and reduced in 3 patients. We conclude, based on our preliminary experience, that an implantable cardioverter/defibrillator can be successfully used with a nonepicardial lead system for endocardial defibrillation in many patients. This lead system can be used with currently available pulse generators and should be considered at cardioverter/defibrillator implantation. It can be anticipated to reduce patient risk and hospital costs associated with this procedure.

Entities:  

Mesh:

Year:  1989        PMID: 2802898

Source DB:  PubMed          Journal:  Arch Intern Med        ISSN: 0003-9926


  4 in total

1.  The leadless defibrillator or the return of the subcutaneous electrode: episode III in the ICD saga?

Authors:  Sanjeev Saksena
Journal:  J Interv Card Electrophysiol       Date:  2005-09       Impact factor: 1.900

2.  [Influence of waveform and configuration of electrodes on the defibrillation threshold of implantable cardioverter-defibrillators].

Authors:  M Block; D Hammel; G Breithardt
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-03

Review 3.  The future of implantable defibrillator and cardiac resynchronization therapy trials.

Authors:  Sanjeev Saksena; Rangadham Nagarakanti
Journal:  J Interv Card Electrophysiol       Date:  2008-08-29       Impact factor: 1.900

4.  Role of proximal electrode position in transvenous ventricular defibrillation.

Authors:  J Nitta; D S Khoury
Journal:  Ann Biomed Eng       Date:  1996 May-Jun       Impact factor: 3.934

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.