Literature DB >> 28027273

Oxygen Tension Beneath Scleral Lenses of Different Clearances.

Claude J Giasson1, Jeanne Morency, Marc Melillo, Langis Michaud.   

Abstract

PURPOSE: To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400).
METHODS: During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA.
RESULTS: The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P < .05) for SL200 and SL400, respectively. Both pO2 measurements fall short of the theoretical values needed to prevent hypoxia during lens wear (9.9% and above).
CONCLUSIONS: As shown in vivo for the first time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28027273     DOI: 10.1097/OPX.0000000000001038

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  4 in total

1.  Optical Impact of Corneal Clearance in Healthy Eyes Fitted with Scleral Contact Lenses: A Pilot Study.

Authors:  María Villa; Francisco Cavas; David P Piñero
Journal:  J Clin Med       Date:  2022-06-14       Impact factor: 4.964

2.  Acute hypoxia influences collagen and matrix metalloproteinase expression by human keratoconus cells in vitro.

Authors:  Tina B McKay; Jesper Hjortdal; Shrestha Priyadarsini; Dimitrios Karamichos
Journal:  PLoS One       Date:  2017-04-20       Impact factor: 3.240

Review 3.  Therapeutic uses of scleral contact lenses for ocular surface disease: patient selection and special considerations.

Authors:  Jennifer S Harthan; Ellen Shorter
Journal:  Clin Optom (Auckl)       Date:  2018-07-11

4.  Identification of Leukocytes Associated With Midday Fogging in the Post-Lens Tear Film of Scleral Contact Lens Wearers.

Authors:  Cameron K Postnikoff; Andrew D Pucker; John Laurent; Carrie Huisingh; Gerald McGwin; Jason J Nichols
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-01-02       Impact factor: 4.799

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.