Literature DB >> 28025681

Dynamic assessment of sling function on transperineal ultrasound: does it correlate with outcomes 1 year following surgery?

Aparna Hegde1,2, Mayte Nogueiras3, Vivian C Aguilar3, G Willy Davila3.   

Abstract

INTRODUCTION AND HYPOTHESIS: To correlate dynamic assessment of sling function using 2D and 3D transperineal ultrasound with outcomes following transobturator sling surgery.
METHODS: This is an unmatched case-control study of 100 patients who underwent transobturator sling surgery at our center between 2009 and 2012. Group A (n = 50) patients had successful outcomes and group B (n = 50) patients had suboptimal outcomes 1 year following surgery. The patients underwent 2D dynamic and 3D transperineal ultrasound. The two groups were compared with regard to the deformability of the sling on Valsalva, the concordance of urethral movement with the sling, and location of the sling.
RESULTS: When compared with group B, group A had a significantly greater number of patients in whom the sling deformed at Valsalva (flat at rest, curving into a c-shape at Valsalva), the urethral movement was concordant with the sling and the sling had a midurethral location (p < 0.0001). In all 17 patients in group B in whom the urethra moved in a concordant manner with the sling (34%), the sling did not deform on Valsalva maneuver and was located proximally. In all 15 patients in group A in whom the sling remained either flat or curved (30%), the urethra moved concordant with the sling and the sling was in midurethral location.
CONCLUSIONS: On 2D and 3D transperineal ultrasound, the best outcomes following transobturator sling surgery are associated with concordance of urethral movement with the sling, midurethral location, and deformability of the sling on dynamic assessment.

Entities:  

Keywords:  Dynamic assessment; Outcomes; Sling function; Sling surgery; Ultrasound

Mesh:

Year:  2016        PMID: 28025681     DOI: 10.1007/s00192-016-3234-y

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  16 in total

1.  Re: Ruth C. Lovegrove Jones, Qiyu Peng, Maria Stokes, Victor F. Humphrey, Christopher Payne, Christos E. Constantinou. Mechanisms of pelvic floor muscle function and the effect on the urethra during a cough. Eur Urol 2010;57:1101-10.

Authors:  Peter E P Petros
Journal:  Eur Urol       Date:  2010-07-15       Impact factor: 20.096

Review 2.  Tension-free transobturator tape procedure for stress urinary incontinence.

Authors:  Mat H Ho; Lawrence L Lin; Alexandra L Haessler; Narender N Bhatia
Journal:  Curr Opin Obstet Gynecol       Date:  2006-10       Impact factor: 1.927

3.  Correlation of tape location and tension with surgical outcome after transobturator suburethral tape procedures.

Authors:  J-M Yang; S-H Yang; W-C Huang; C-R Tzeng
Journal:  Ultrasound Obstet Gynecol       Date:  2012-03-12       Impact factor: 7.299

Review 4.  An integral theory of female urinary incontinence. Experimental and clinical considerations.

Authors:  P E Petros; U I Ulmsten
Journal:  Acta Obstet Gynecol Scand Suppl       Date:  1990

5.  Visibility of the polypropylene tape after tension-free vaginal tape (TVT) procedure in women with stress urinary incontinence: comparison of introital ultrasound and magnetic resonance imaging in vitro and in vivo.

Authors:  S Schuettoff; D Beyersdorff; A Gauruder-Burmester; R Tunn
Journal:  Ultrasound Obstet Gynecol       Date:  2006-06       Impact factor: 7.299

6.  Tape functionality: sonographic tape characteristics and outcome after TVT incontinence surgery.

Authors:  Jacek Kociszewski; Oliver Rautenberg; Daniele Perucchini; Jakob Eberhard; Verena Geissbühler; Reinhard Hilgers; Volker Viereck
Journal:  Neurourol Urodyn       Date:  2008       Impact factor: 2.696

7.  Ultrasonographic assessment of tape location following tension-free vaginal tape and transobturator tape procedure.

Authors:  Cheng-Yu Long; Chun-Shuo Hsu; Tsia-Shu Lo; Cheng-Min Liu; Yung-Hung Chen; Eing-Mei Tsai
Journal:  Acta Obstet Gynecol Scand       Date:  2008       Impact factor: 3.636

8.  Ultrasonographic and urodynamic evaluation after tension free vagina tape procedure (TVT).

Authors:  T S Lo; A C Wang; S G Horng; C C Liang; Y K Soong
Journal:  Acta Obstet Gynecol Scand       Date:  2001-01       Impact factor: 3.636

9.  Correlation of morphological alterations and functional impairment of the tension-free vaginal tape obturator procedure.

Authors:  Jenn-Ming Yang; Shwu-Huey Yang; Wen-Chen Huang
Journal:  J Urol       Date:  2008-11-14       Impact factor: 7.450

10.  A prospective multicenter randomized trial of tension-free vaginal tape and colposuspension for primary urodynamic stress incontinence: two-year follow-up.

Authors:  Karen L Ward; Paul Hilton
Journal:  Am J Obstet Gynecol       Date:  2004-02       Impact factor: 8.661

View more
  7 in total

1.  Pelvic floor ultrasound in the diagnosis of sling complications.

Authors:  Lewis Chan; Vincent Tse
Journal:  World J Urol       Date:  2018-03-12       Impact factor: 4.226

Review 2.  Clinical application of 2D and 3D pelvic floor ultrasound of mid-urethral slings and vaginal wall mesh.

Authors:  Annika Taithongchai; Abdul H Sultan; Pawel A Wieczorek; Ranee Thakar
Journal:  Int Urogynecol J       Date:  2019-05-11       Impact factor: 2.894

3.  Using clinical estimate or catheter measurement of urethral mid-point result in similar retropubic mid-urethral sling position: a randomized trial.

Authors:  H C Barnes; A Akl; S K Taege; C Brincat; L Brubaker; E R Mueller
Journal:  Int Urogynecol J       Date:  2022-03-30       Impact factor: 2.894

4.  Transobturator tape versus single incision sling: how are they different? Clinical outcomes and ultrasonographic features of two mid-urethral slings.

Authors:  Daniela Caramazza; Giuseppe Campagna; Francesca Moro; Lorenzo Vacca; Monia Marturano; Sara Pizzacalla; Ilaria Nausica Trivellizzi; Giovanni Panico; Giovanni Scambia; Alfredo Ercoli; Antonia Carla Testa
Journal:  World J Urol       Date:  2022-08-18       Impact factor: 3.661

5.  New frontiers in molecular and imaging research on evaluation and diagnosis of bladder outlet obstruction in women.

Authors:  Laura Martinez; Rose Khavari
Journal:  Curr Bladder Dysfunct Rep       Date:  2017-08-04

6.  Construction of a Prognostic Score for Ultrasound Evaluation of the Transobturator Sling for Stress Urinary Incontinence.

Authors:  Espada-Gonzalez Cristina; Sabonet-Morente Lorena; Perez-Gonzalez Rita; Gonzalez-Mesa Ernesto Santiago; Jimenez-Lopez Jesus Salvador
Journal:  J Clin Med       Date:  2022-02-27       Impact factor: 4.241

7.  Translabial ultrasound: a non-invasive technique for assessing "technical errors" after TOT failure.

Authors:  Ester Illiano; Francesco Trama; Vincenzo Li Marzi; Vito Mancini; Giuseppe Carrieri; Claudia Collà Ruvolo; Gianluigi Califano; Consuelo Fabi; Stefano Brancorsini; Elisabetta Costantini
Journal:  Int Urogynecol J       Date:  2021-06-30       Impact factor: 1.932

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.