Literature DB >> 2802517

Hemoglobin by first derivative spectrophotometry: extent of hemolysis in plasma and serum collected in vacuum container devices.

B E Copeland1, P J Dyer, A J Pesce.   

Abstract

Commonly obtained clear plasma or serum samples contain small amounts of hemoglobin derived from either naturally occurring processes or from collection trauma. Using the recently evaluated, highly specific, sensitive, quantitative procedure of first derivative spectroscopy, the hemoglobin concentration in nine types of vacuum collection containers was measured, including three types of anticoagulant, three tube sizes, and tubes with or without serum separators. Using this procedure, reference values were established for plasma and serum hemoglobin. These values are the result of the combined effect of red cell trauma during the collection, interaction with the anticoagulant or the serum separator material, and physiologic changes. The observed hemoglobin levels were best described by a log normal distribution pattern. The three plasma collection samples showed lower average values than the serum samples. The citrate anticoagulant gave the lowest plasma hemoglobin average value of 32.7 mg per L (3.27 mg per dl) 9.2 to 123 mg per L (0.92 to 12.3 mg per L 2SD range). It is concluded that the average hemoglobin concentration owing to the collection procedure is less than 100 mg per L (10 mg per dl). A serum or plasma hemoglobin concentration over 200 mg per L (20 mg per dl) is probably due to abnormal physiologic causes and not collection artefact. Serum or plasma hemoglobin measurements evaluated by these criteria can be relied upon as an accurate approximation of excess hemoglobin produced by a pathologic hemolytic process such as acute autoimmune hemolytic anemia, major blood group incompatibility or paroxysmal hemoglobinuria.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2802517

Source DB:  PubMed          Journal:  Ann Clin Lab Sci        ISSN: 0091-7370            Impact factor:   1.256


  4 in total

1.  Phase I trial of pelvic radiation, weekly cisplatin, and 3-aminopyridine-2-carboxaldehyde thiosemicarbazone (3-AP, NSC #663249) for locally advanced cervical cancer.

Authors:  Charles A Kunos; Steven Waggoner; Vivian von Gruenigen; Elisa Eldermire; John Pink; Afshin Dowlati; Timothy J Kinsella
Journal:  Clin Cancer Res       Date:  2010-02-09       Impact factor: 12.531

Review 2.  Management of 3-aminopyridine-2-carboxaldehyde thiosemicarbazone-induced methemoglobinemia.

Authors:  Charles A Kunos; Tomas Radivoyevitch; Stephen T Ingalls; Charles L Hoppel
Journal:  Future Oncol       Date:  2012-02       Impact factor: 3.404

3.  An apoA-I mimetic peptide containing a proline residue has greater in vivo HDL binding and anti-inflammatory ability than the 4F peptide.

Authors:  Geoffrey D Wool; Tomas Vaisar; Catherine A Reardon; Godfrey S Getz
Journal:  J Lipid Res       Date:  2009-05-11       Impact factor: 5.922

4.  Sex differences and associations between zinc deficiency and anemia among hospitalized adolescents and young adults with eating disorders.

Authors:  Jason M Nagata; Paola Bojorquez-Ramirez; Anthony Nguyen; Kyle T Ganson; Christine M McDonald; Vanessa I Machen; Amanda Downey; Sara M Buckelew; Andrea K Garber
Journal:  Eat Weight Disord       Date:  2022-05-28       Impact factor: 3.008