Literature DB >> 28025151

Normative 3D acetabular orientation measurements by the low-dose EOS imaging system in 102 asymptomatic subjects in standing position: Analyses by side, gender, pelvic incidence and reproducibility.

T Thelen1, P Thelen2, H Demezon1, S Aunoble1, J-C Le Huec3.   

Abstract

BACKGROUND: Three-dimensional (3D) acetabular orientation is a fundamental topic in orthopedic surgery. Computed tomography (CT) allows 3D measurement of native acetabular orientation, but with a substantial radiation dose. The EOS imaging system was developed to perform this kind of evaluation, but has not been validated in this indication with specific attention to the acetabulum. We therefore performed a prospective study using EOS to assess: (1) the reproducibility of the 3D acetabulum orientation measures; (2) normative asymptomatic acetabular morphology in standing position, according to side and gender; and (3) the relationship between acetabular anteversion and pelvic incidence. HYPOTHESIS: The low-dose EOS imaging system is a reproducible method for measuring 3D acetabular orientation in standing position. PATIENTS AND METHODS: In a previous prospective study of spine sagittal balance, 165 asymptomatic volunteers were examined on whole-body EOS biplanar X-ray; 102 had appropriate images for pelvic and acetabular analysis, with an equal sex-ratio (53 female, 49 male). These EOS images were reviewed using sterEOS 3D software, allowing automatic measurement of acetabular parameters (anteversion and inclination) and pelvic parameters (pelvic incidence, pelvic tilt and sacral slope) in an anatomical (anterior pelvic plane: APP) and a functional reference plane (patient vertical plane: PVP).
RESULTS: Both intra- and inter-observer analysis showed good agreement (ICC>0.90); Bland-Altman plot distributions were good. Acetabular anatomical anteversion and inclination relative to APP (AAAPP and AIAPP, respectively) were significantly greater in women than in men, with no effect of side (right AAA: women 21.3°±3.4° vs. men 16.1°±3.3° (P<0001); right AIAPP: women 55.3°±3.7° vs. men 52.5°±3.0° (P<0001); left AAAPP: women 20.9°±3.5° vs. men 15.6°±4.0° (P<0001); left AIAPP: women 54.6°±3.5° vs. men 52.7°±2.8° (P=0003)). The same differences between men and women were observed when measurements were related to PVP. Pelvic incidence subgroup (<44°; 44-62°; >62°) correlated significantly with functional acetabular orientation in standing position: PVP functional anteversion decreased by 5° relative to APP anteversion with incidence <44°, was equal to APP with incidence 44-62°, and or was greater by 4° relative to APP with incidence >62°. DISCUSSION: The use of a 3D sterEOS software prototype version for 3D reconstruction of the native acetabulum from standard EOS X-ray was shown to be a reliable and reproducible method. This innovative method enabled the reference values of 3D acetabular orientation in standing position to be measured for the first time. The results reinforced the concept of hip-spine relationships, and involved very low radiation dose. LEVEL OF EVIDENCE: IV prospective study without control group.
Copyright © 2016 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  3D orientation; Asymptomatic subjects; EOS; Native acetabulum

Mesh:

Year:  2016        PMID: 28025151     DOI: 10.1016/j.otsr.2016.11.010

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  6 in total

1.  Toward understanding the underlying mechanisms of pelvic tilt reserve in adult spinal deformity: the role of the 3D hip orientation.

Authors:  Mario Mekhael; Georges Kawkabani; Renée Maria Saliby; Wafa Skalli; Eddy Saad; Elena Jaber; Rami Rachkidi; Khalil Kharrat; Gaby Kreichati; Ismat Ghanem; Virginie Lafage; Ayman Assi
Journal:  Eur Spine J       Date:  2021-02-27       Impact factor: 3.134

2.  The relationship between pelvic incidence and anatomical acetabular anteversion in female Japanese patients with hip osteoarthritis: a retrospective iconographic study.

Authors:  Takaomi Kobayashi; Tadatsugu Morimoto; Tomohito Yoshihara; Motoki Sonohata; Charles Rivière; Masaaki Mawatari
Journal:  Surg Radiol Anat       Date:  2021-02-24       Impact factor: 1.246

3.  Kinematic alignment technique for total hip and knee arthroplasty: The personalized implant positioning surgery.

Authors:  Charles Rivière; Stefan Lazic; Loïc Villet; Yann Wiart; Sarah Muirhead Allwood; Justin Cobb
Journal:  EFORT Open Rev       Date:  2018-03-29

4.  Current concepts in robotic total hip arthroplasty.

Authors:  Pascal Kouyoumdjian; Jad Mansour; Chahine Assi; Jacques Caton; Sebastien Lustig; Remy Coulomb
Journal:  SICOT J       Date:  2020-11-27

5.  No linear correlation between pelvic incidence and acetabular orientation: Retrospective observational study.

Authors:  Jung-Taek Kim; Quan Hu Shen; Chang-Hoon Jeon; Nam-Su Chung; Seungmin Jeong; Han-Dong Lee
Journal:  Medicine (Baltimore)       Date:  2021-04-16       Impact factor: 1.889

6.  Acetabular Morphology and Spinopelvic Characteristics: What Predominantly Determines Functional Acetabular Version?

Authors:  Zachary DeVries; Andrew D Speirs; Saif Salih; Paul E Beaulé; Johan Witt; George Grammatopoulos
Journal:  Orthop J Sports Med       Date:  2021-10-22