Literature DB >> 28024815

Fit of pressed crowns fabricated from two CAD-CAM wax pattern process plans: A comparative in vitro study.

Loubna Shamseddine1, Rola Mortada2, Khaldoun Rifai3, Jose Johann Chidiac3.   

Abstract

STATEMENT OF PROBLEM: Subtractive and additive computer-aided design and computer-aided manufacturing (CAD-CAM) wax pattern processing are 2 methods of fabricating a pressed ceramic crown. Whether a subtractive milled wax pattern or a pattern from the micro-stereolithography additive process produces lithium disilicate crowns with better marginal and internal fit is unclear.
MATERIALS AND METHODS: Ten silicone impressions were made for a prepared canine tooth. Each die received 2 lithium disilicate (IPS e.max) copings, 1 from milled wax blocks and 1 from additive wax. The replica technique was used to measure the fit by scanning electron microscopy at ×80 magnification. Collected data were analyzed using the paired Student t test for the marginal and internal fit. For the occlusal fit, the difference in scores did not follow a normal distribution, and the Wilcoxon signed rank test was used (α=.05).
RESULTS: The mean marginal, axial, and occlusal fit showed no significant differences when the 2 CAD-CAM manufacturing processes were compared (P>.05). For the marginal fit, the mean (±SD) values were 105.1 μm ±39.6 with the milled process and 126.2 μm ±25.2 for the additive process. The mean values were 98.1 μm ±26.1 for the axial fit in the milled process and 106.8 μm ±21.2 in the additive process. For the occlusal fit, median values (interquartile interval) were 199.0 μm (141.5 to 269.9) for subtractive manufacturing and 257.2 μm (171.6 to 266.0) for micro-SLA manufacturing.
CONCLUSIONS: No significant difference was found between the fit of the 2 techniques. The mean values of axial and occlusal median values were 10 and 5 to 6 times greater than machine's nominal values.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 28024815     DOI: 10.1016/j.prosdent.2016.10.003

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study.

Authors:  Hyun-Wook Woo; Sung-Am Cho; Cheong-Hee Lee; Kyu-Bok Lee; Jin-Hyun Cho; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

2.  Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study.

Authors:  Beom-Il Lee; Seung-Gyu You; Seung-Min You; Seen-Young Kang; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2021-02-23       Impact factor: 1.904

3.  Effect of Different Wax Pattern Manufacturing Techniques on the Marginal Fit of Lithium Disilicate Crowns.

Authors:  Huda Ahmed Alshehri; Sara Mohammed Altaweel; Raghdah Alshaibani; Esraa Ahmed Alahmari; Hanan Nejer Alotaibi; Afnan Fouzan Alfouzan; Nawaf Labban
Journal:  Materials (Basel)       Date:  2022-07-07       Impact factor: 3.748

4.  Evaluation of marginal discrepancy of pressable ceramic veneer fabricated using CAD/CAM system: Additive and subtractive manufacturing.

Authors:  Seen-Young Kang; Ha-Na Lee; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2018-10-22       Impact factor: 1.904

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.