Literature DB >> 28024637

Effect of Ca/P ratio on the structural and corrosion properties of biomimetic CaP coatings on ZK60 magnesium alloy.

Kada Xia1, Hui Pan2, Taolei Wang1, Shangjun Ma1, Junchao Niu1, Zhen Xiang1, Yiming Song1, Huawei Yang2, Xiaoshan Tang2, Wei Lu3.   

Abstract

Magnesium and its alloys have attracted much attention as metallic biodegradable implants for their excellent biocompatibility and mechanical properties. However, magnesium has a poor corrosion resistance, causing its rapid degrading in vivo via an electrochemical reaction, which has become a major obstacle to their applications in implants. In this work, CaP coating was successfully coated on the ZK60 magnesium alloys by a simple hydrothermal deposition method. The mechanisms of the hydrothermal reactions of CaP coatings on Mg substrate are described in details. The effect of Ca/P ratio in the hydrothermal solution on the phase composition, microstructure and biodegradation properties of CaP coatings on ZK60 alloys was investigated by varying the Ca/P ratio from 0.83 to 4.18. The morphology of the CaP coating changed significantly with the Ca/P ratio. Biodegradation behavior of the CaP coating magnesium was characterized by anodic polarization and immersion tests in a simulated body fluid. It is revealed that the corrosion resistance of ZK60 magnesium alloy was greatly improved with the biomimetic CaP coatings, and the ZK60 alloy with CaP coating deposited at Ca/P ratio of 1.67 has the best corrosion resistance, which indicates that the CaP coatings are promising for improving the biodegradation properties of Mg-based orthopedic implants and devices.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  Biodegradation; Ca-P coating; Ca/P ratio; Hydrothermal deposition; Magnesium alloy

Mesh:

Substances:

Year:  2016        PMID: 28024637     DOI: 10.1016/j.msec.2016.11.132

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  2 in total

1.  In vitro corrosion resistance of layer-by-layer assembled polyacrylic acid multilayers induced Ca-P coating on magnesium alloy AZ31.

Authors:  Lan-Yue Cui; Shen-Cong Cheng; Lu-Xian Liang; Jing-Chao Zhang; Shuo-Qi Li; Zhen-Lin Wang; Rong-Chang Zeng
Journal:  Bioact Mater       Date:  2020-02-10

Review 2.  Analytical Techniques for the Characterization of Bioactive Coatings for Orthopaedic Implants.

Authors:  Katja Andrina Kravanja; Matjaž Finšgar
Journal:  Biomedicines       Date:  2021-12-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.