Literature DB >> 28018714

Multi-modal automatic montaging of adaptive optics retinal images.

Min Chen1, Robert F Cooper2, Grace K Han2, James Gee3, David H Brainard4, Jessica I W Morgan2.   

Abstract

We present a fully automated adaptive optics (AO) retinal image montaging algorithm using classic scale invariant feature transform with random sample consensus for outlier removal. Our approach is capable of using information from multiple AO modalities (confocal, split detection, and dark field) and can accurately detect discontinuities in the montage. The algorithm output is compared to manual montaging by evaluating the similarity of the overlapping regions after montaging, and calculating the detection rate of discontinuities in the montage. Our results show that the proposed algorithm has high alignment accuracy and a discontinuity detection rate that is comparable (and often superior) to manual montaging. In addition, we analyze and show the benefits of using multiple modalities in the montaging process. We provide the algorithm presented in this paper as open-source and freely available to download.

Keywords:  (100.0100) Image processing; (110.1080) Active or adaptive optics; (170.4470) Ophthalmology

Year:  2016        PMID: 28018714      PMCID: PMC5175540          DOI: 10.1364/BOE.7.004899

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  13 in total

Review 1.  Mutual-information-based registration of medical images: a survey.

Authors:  Josien P W Pluim; J B Antoine Maintz; Max A Viergever
Journal:  IEEE Trans Med Imaging       Date:  2003-08       Impact factor: 10.048

2.  Packing arrangement of the three cone classes in primate retina.

Authors:  A Roorda; A B Metha; P Lennie; D R Williams
Journal:  Vision Res       Date:  2001       Impact factor: 1.886

Review 3.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

4.  Supernormal vision and high-resolution retinal imaging through adaptive optics.

Authors:  J Liang; D R Williams; D T Miller
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-11       Impact factor: 2.129

5.  In vivo autofluorescence imaging of the human and macaque retinal pigment epithelial cell mosaic.

Authors:  Jessica I W Morgan; Alfredo Dubra; Robert Wolfe; William H Merigan; David R Williams
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-10-24       Impact factor: 4.799

6.  Symmetric diffeomorphic image registration with cross-correlation: evaluating automated labeling of elderly and neurodegenerative brain.

Authors:  B B Avants; C L Epstein; M Grossman; J C Gee
Journal:  Med Image Anal       Date:  2007-06-23       Impact factor: 8.545

Review 7.  The fundus photo has met its match: optical coherence tomography and adaptive optics ophthalmoscopy are here to stay.

Authors:  Jessica I W Morgan
Journal:  Ophthalmic Physiol Opt       Date:  2016-05       Impact factor: 3.117

8.  Reflective afocal broadband adaptive optics scanning ophthalmoscope.

Authors:  Alfredo Dubra; Yusufu Sulai
Journal:  Biomed Opt Express       Date:  2011-05-27       Impact factor: 3.732

9.  Noninvasive imaging of the human rod photoreceptor mosaic using a confocal adaptive optics scanning ophthalmoscope.

Authors:  Alfredo Dubra; Yusufu Sulai; Jennifer L Norris; Robert F Cooper; Adam M Dubis; David R Williams; Joseph Carroll
Journal:  Biomed Opt Express       Date:  2011-06-08       Impact factor: 3.732

10.  The use of forward scatter to improve retinal vascular imaging with an adaptive optics scanning laser ophthalmoscope.

Authors:  Toco Y P Chui; Dean A Vannasdale; Stephen A Burns
Journal:  Biomed Opt Express       Date:  2012-09-13       Impact factor: 3.732

View more
  27 in total

1.  Long eye relief fundus camera and fixation target with partial correction of ocular longitudinal chromatic aberration.

Authors:  Samuel Steven; Yusufu N Sulai; Soon K Cheong; Julie Bentley; Alfredo Dubra
Journal:  Biomed Opt Express       Date:  2018-11-07       Impact factor: 3.732

2.  Interocular Symmetry of Foveal Cone Topography in Congenital Achromatopsia.

Authors:  Katie M Litts; Michalis Georgiou; Christopher S Langlo; Emily J Patterson; Rebecca R Mastey; Angelos Kalitzeos; Rachel E Linderman; Byron L Lam; Gerald A Fishman; Mark E Pennesi; Christine N Kay; William W Hauswirth; Michel Michaelides; Joseph Carroll
Journal:  Curr Eye Res       Date:  2020-03-13       Impact factor: 2.424

Review 3.  Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update.

Authors:  Bing Zhang; Ni Li; Jie Kang; Yi He; Xiao-Ming Chen
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

4.  Automatic longitudinal montaging of adaptive optics retinal images using constellation matching.

Authors:  Min Chen; Robert F Cooper; James C Gee; David H Brainard; Jessica I W Morgan
Journal:  Biomed Opt Express       Date:  2019-11-25       Impact factor: 3.732

5.  Polynomial transformation model for frame-to-frame registration in an adaptive optics confocal scanning laser ophthalmoscope.

Authors:  Hao Chen; Yi He; Ling Wei; Jinsheng Yang; Xiqi Li; Guohua Shi; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2019-08-12       Impact factor: 3.732

6.  Evaluating seasonal changes of cone photoreceptor structure in the 13-lined ground squirrel.

Authors:  Benjamin S Sajdak; Alexander E Salmon; Katie M Litts; Clive Wells; Kenneth P Allen; Alfredo Dubra; Dana K Merriman; Joseph Carroll
Journal:  Vision Res       Date:  2019-03-07       Impact factor: 1.886

7.  Visual Acuity and Foveal Structure in Eyes with Fragmented Foveal Avascular Zones.

Authors:  Rachel E Linderman; Jenna A Cava; Alexander E Salmon; Toco Y Chui; Alan D Marmorstein; Brandon J Lujan; Richard B Rosen; Joseph Carroll
Journal:  Ophthalmol Retina       Date:  2019-11-22

8.  Fully Automated Estimation of Spacing and Density for Retinal Mosaics.

Authors:  Robert F Cooper; Geoffrey K Aguirre; Jessica I W Morgan
Journal:  Transl Vis Sci Technol       Date:  2019-10-17       Impact factor: 3.283

9.  The Reliability of Cone Density Measurements in the Presence of Rods.

Authors:  Jessica I W Morgan; Grace K Vergilio; Jessica Hsu; Alfredo Dubra; Robert F Cooper
Journal:  Transl Vis Sci Technol       Date:  2018-06-22       Impact factor: 3.283

10.  Emulated retinal image capture (ERICA) to test, train and validate processing of retinal images.

Authors:  Laura K Young; Hannah E Smithson
Journal:  Sci Rep       Date:  2021-05-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.