Literature DB >> 28017260

Comparison of dissection with harmonic scalpel and conventional bipolar electrocautery in deep inferior epigastric perforator flap surgery: A consecutive cohort study.

Yoon Jae Lee1, Hak Young Kim1, Hyun Ho Han1, Suk-Ho Moon1, Jun Hee Byeon2, Jong Won Rhie1, Sang Tae Ahn1, Deuk Young Oh3.   

Abstract

Reduced tissue damage is a theoretical advantage of using an ultrasonic harmonic scalpel. We hypothesized that the harmonic scalpel would outperform electrocautery in deep inferior epigastric perforator flap surgery, possibly resulting in a shorter operative time and reduced postoperative drainage and pain. Between January and August 2015, 24 consecutive patients were assigned to immediate deep inferior epigastric perforator flap elevation (12 for bipolar electrocautery and 12 for harmonic scalpel). The main outcome variables were total operative time, flap elevation time (starting from the fascia incision), and drainage volume. We compared the number of perforators isolated and the Moon and Taylor classification of the pedicle. Data were tested for normality using the Kolmogorov-Smirnov test before analysis. Continuous variables were compared by Wilcoxon rank-sum test. Data were analyzed using the statistical software SAS, version 9.3 (SAS Institute, Cary, NC, USA). Both groups were comparable with respect to clinical characteristics (mean age, body mass index, and flap weights). There was a statistically significant difference in the operative time between dissection with the harmonic scalpel and electrocautery (305.2 vs. 380.3 min, respectively, p = 0.002). The flap elevation time was reduced, particularly when using the harmonic scalpel where its usage seems crucial for dissecting deep inferior epigastric perforators (59.8 vs. 145.9 min, respectively, p < 0.0001). No statistical difference was observed in the drainage volume and length of hospital stay between the groups. We conclude that the harmonic scalpel may be more reliable and efficient as an alternative to electrocautery.
Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Breast reconstruction; Dissection; Electrocautery; Ultrasonic

Mesh:

Year:  2016        PMID: 28017260     DOI: 10.1016/j.bjps.2016.11.005

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  3 in total

1.  Diametric Comparison between the Thoracodorsal Vessel and Deep Inferior Epigastric Vessel in Breast Reconstruction.

Authors:  Jun Hyeok Kim; Ye Sol Kim; Suk-Ho Moon; Young Joon Jun; Jong Won Rhie; Deuk Young Oh
Journal:  Biomed Res Int       Date:  2020-07-16       Impact factor: 3.411

2.  Hemostasis with the Ultrasonic Scalpel.

Authors:  Claudio Peixoto Crispi; Claudio Peixoto Crispi; Paulo Sergio da Silva Reis; Fernando Luis Fernandes Mendes; Marina Mattos Filgueiras; Marlon de Freitas Fonseca
Journal:  JSLS       Date:  2018 Oct-Dec       Impact factor: 2.172

3.  Delayed periprosthetic seroma in a male Poland syndrome patient: A case report.

Authors:  Jangyoun Choi; Jung Hyeou Kim; Yeoun Eun Sung; Deuk Young Oh
Journal:  Medicine (Baltimore)       Date:  2021-03-12       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.