Literature DB >> 28009421

Phase II multi-institutional clinical trial on a new mixed beam RT scheme of IMRT on pelvis combined with a carbon ion boost for high-risk prostate cancer patients.

Giulia Marvaso1, Barbara A Jereczek-Fossa1,2, Barbara Vischioni3, Delia Ciardo1, Tommaso Giandini4, Azusa Hasegawa3, Federica Cattani5, Mauro Carrara4, Mario Ciocca6, Nice Bedini7, Sergio Villa7, Sara Morlino7, Stefania Russo6, Dario Zerini1, Sarah Pia Colangione1, Costanza Maria Vittoria Panaino4, Cristiana Fodor1, Luigi Santoro8, Emanuele Pignoli4, Francesca Valvo3, Riccardo Valdagni7,2, Ottavio De Cobelli9, Roberto Orecchia10,2.   

Abstract

PURPOSE: Definition of the optimal treatment schedule for high-risk prostate cancer is under debate. A combination of photon intensity modulated radiotherapy (IMRT) on pelvis with a carbon ion boost might be the optimal treatment scheme to escalate the dose on prostate and deliver curative dose with respect to normal tissue and quality of dose distributions. In fact, carbon ion beams offer the advantage to deliver hypofractionated radiotherapy (RT) using a significantly smaller number of fractions compared to conventional RT without increasing risks of late effects.
METHODS: This study is a prospective phase II clinical trial exploring safety and feasibility of a mixed beam scheme of carbon ion prostate boost followed by photon IMRT on pelvis. The study is designed to enroll 65 patients with localized high-risk prostate cancer at 3 different oncologic hospitals: Istituto Europeo di Oncologia, Fondazione IRCCS Istituto Nazionale dei Tumori, and Centro Nazionale di Adroterapia Oncologica. The primary endpoint is the evaluation of safety and feasibility with acute toxicity scored up to 1 month after the end of RT. Secondary endpoints are treatment early (3 months after the end of RT) and long-term tolerability, quality of life, and efficacy.
RESULTS: The study is not yet recruiting; in silico studies are ongoing and we expect to start recruitment by 2017.
CONCLUSIONS: The present clinical trial aims at improving the current treatment for high-risk prostate cancer, evaluating safety and feasibility of a new RT mixed-beam scheme including photons and carbon ions. Encouraging results are coming from carbon ion facilities worldwide on the treatment of different tumors including prostate cancers. Carbon ions combine physical properties allowing for high dose conformity and advantageous radiobiological characteristics. The proposed mixed beam treatment has the advantage to combine a photon high conformity standard of care IMRT phase with a hypofractionated carbon ion RT boost delivered in a short overall treatment time.

Entities:  

Mesh:

Year:  2016        PMID: 28009421     DOI: 10.5301/tj.5000587

Source DB:  PubMed          Journal:  Tumori        ISSN: 0300-8916            Impact factor:   2.098


  3 in total

Review 1.  Clinical trials involving carbon-ion radiation therapy and the path forward.

Authors:  Ann A Lazar; Reinhard Schulte; Bruce Faddegon; Eleanor A Blakely; Mack Roach
Journal:  Cancer       Date:  2018-10-11       Impact factor: 6.860

2.  Hypofractionation in prostate cancer radiotherapy: a step forward towards clinical routine.

Authors:  Barbara Vischioni; Rachele Petrucci; Francesca Valvo
Journal:  Transl Androl Urol       Date:  2019-12

3.  Mixed-Beam Approach for High-Risk Prostate Cancer Carbon-Ion Boost Followed by Photon Intensity-Modulated Radiotherapy: Preliminary Results of Phase II Trial AIRC-IG-14300.

Authors:  Giulia Marvaso; Barbara Vischioni; Matteo Pepa; Mattia Zaffaroni; Stefania Volpe; Filippo Patti; Federica Bellerba; Sara Gandini; Stefania Comi; Giulia Corrao; Dario Zerini; Matteo Augugliaro; Cristiana Fodor; Stefania Russo; Silvia Molinelli; Mario Ciocca; Rosalinda Ricotti; Francesca Valvo; Tommaso Giandini; Barbara Avuzzi; Riccardo Valdagni; Ottavio De Cobelli; Federica Cattani; Ester Orlandi; Barbara Alicja Jereczek-Fossa; Roberto Orecchia
Journal:  Front Oncol       Date:  2021-11-17       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.