Abstract

BACKGROUND: Metallic ball heads for total hip replacement (THR) bearings with ceramicized surfaces were introduced in orthopedics during the second half of the 1980s, with the aim of decreasing the wear of polyethylene cups.
METHODS: An analysis was made of the literature regarding outcomes for metallic ball heads with ceramicized surfaces now in clinical use (TiN, TiNbN, ZrN, monoclinic ZrO2), as well as carbon coatings (pyrolytic carbon, diamond-like carbon) and silicon nitride as coatings in ball heads for THR bearings.
RESULTS: Notwithstanding the diffusion of ceramicized ball heads in THRs, there are few reports about their clinical outcomes in hip arthroplasty. In addition, several clinical studies and some registry data are putting under scrutiny the clinical advantages of ceramicized ball heads over cobalt chrome (CoCr) alloy and ceramic ball heads.
CONCLUSIONS: The wear of THR bearings with ceramicized ball heads looks like it depends more on the behavior of the polyethylene cups than on the treatment of the ball head surface. The risk of coating damage and of its consequences has to be taken into account in selecting this type of bearing.

Entities:  

Mesh:

Year:  2017        PMID: 28009420     DOI: 10.5301/jabfm.5000330

Source DB:  PubMed          Journal:  J Appl Biomater Funct Mater        ISSN: 2280-8000            Impact factor:   2.604


  6 in total

Review 1.  New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.

Authors:  Preston W Grieco; Scott Pascal; Jared M Newman; Neil V Shah; Sarah G Stroud; Neil P Sheth; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-27

2.  Observation of Anesthetic Effect of Dexmedetomidine Combined With Intraspinal Anesthesia in Hip Arthroplasty and its Effect on Postoperative Delirium and Stress Response.

Authors:  Yading Shen; Chenyu Wang; Xiaoping Zhong; Yandan Wu; Xiaoxia He
Journal:  Front Surg       Date:  2022-07-01

3.  Hip and knee replacement in patients with ochronosis: Clinical experience and literature review.

Authors:  Cesare Meschini; Michele Cauteruccio; Maria Serena Oliva; Giuseppe Sircana; Raffaele Vitiello; Giuseppe Rovere; Francesco Muratori; Giulio Maccauro; Antonio Ziranu
Journal:  Orthop Rev (Pavia)       Date:  2020-06-26

4.  Ability of adhesion and biofilm formation of pathogens of periprosthetic joint infections on titanium-niobium nitride (TiNbN) ceramic coatings.

Authors:  Alessandro Bidossi; Marta Bottagisio; Roberta De Grandi; Elena De Vecchi
Journal:  J Orthop Surg Res       Date:  2020-03-04       Impact factor: 2.359

5.  The Effect of Coating Density on Functional Properties of SiNx Coated Implants.

Authors:  Luimar Correa Filho; Susann Schmidt; Alejandro López; Mathilde Cogrel; Klaus Leifer; Håkan Engqvist; Hans Högberg; Cecilia Persson
Journal:  Materials (Basel)       Date:  2019-10-15       Impact factor: 3.623

6.  Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up.

Authors:  Malerba Giuseppe; Basilico Mattia; Bonfiglio Nadia; Vitiello Raffaele; Ruberto Pasquale; D' Adamio Stefano; Sirgiovanni Mattia; De Santis Vincenzo; Maccauro Giulio
Journal:  BMC Musculoskelet Disord       Date:  2022-01-17       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.