Literature DB >> 28008363

Muscular activity and physical interaction forces during lower limb exoskeleton use.

Matthew Wilcox1, Ashish Rathore1, Dafne Zuleima Morgado Ramirez2, Rui C V Loureiro1, Tom Carlson1.   

Abstract

Spinal cord injury (SCI) typically manifests with a loss of sensorimotor control of the lower limbs. In order to overcome some of the disadvantages of chronic wheelchair use by such patients, robotic exoskeletons are an emerging technology that has the potential to transform the lives of patients. However, there are a number of points of contact between the robot and the user, which lead to interaction forces. In a recent study, the authors have shown that peak interaction forces are particularly prominent at the anterior aspect of the right leg. This study uses a similar experimental protocol with additional electromyography (EMG) analysis to examine whether such interaction forces are due to the muscular activity of the participant or the movement of the exoskeleton itself. Interestingly, the authors found that peak forces preceded peak EMG activity. This study did not find a significant correlation between EMG activity and force data, which would indicate that the interaction forces can largely be attributed to the movement of the exoskeleton itself. However, we also report significantly higher correlation coefficients in muscle/force pairs located at the anterior aspect of the right leg. In their previous research, the authors have shown peak interaction forces at the same locations, which suggests that muscular activity of the participant makes a more significant contribution to the interaction forces at these locations. The findings of this study are of significance for incomplete SCI patients, for whom EMG activity may provide an important input to an intuitive control schema.

Entities:  

Keywords:  EMG; SCI; anterior aspect; artificial limbs; chronic wheelchair use; electromyography; electromyography analysis; injuries; intuitive control schema; lower limb exoskeleton use; lower limbs; muscular activity; peak interaction forces; physical interaction forces; right leg; robotic exoskeletons; sensorimotor control; spinal cord injury; wheelchairs

Year:  2016        PMID: 28008363      PMCID: PMC5168818          DOI: 10.1049/htl.2016.0063

Source DB:  PubMed          Journal:  Healthc Technol Lett        ISSN: 2053-3713


  13 in total

Review 1.  Pressure sores.

Authors:  Michael J Bass; Linda G Phillips
Journal:  Curr Probl Surg       Date:  2007-02       Impact factor: 1.909

2.  A method for better positioning bipolar electrodes for lower limb EMG recordings during dynamic contractions.

Authors:  Isabel C N Sacco; Aline A Gomes; Mitie E Otuzi; Denise Pripas; Andrea N Onodera
Journal:  J Neurosci Methods       Date:  2009-03-09       Impact factor: 2.390

3.  The impact of mobility assistive technology devices on participation for individuals with disabilities.

Authors:  Jordan Carver; Ashley Ganus; Jon Mark Ivey; Teresa Plummer; Ann Eubank
Journal:  Disabil Rehabil Assist Technol       Date:  2015-03-27

Review 4.  Evidence-based medicine: pressure sores.

Authors:  Carolyn A Cushing; Linda G Phillips
Journal:  Plast Reconstr Surg       Date:  2013-12       Impact factor: 4.730

5.  Analysis of upper and lower extremity peripheral nerve injuries in a population of patients with multiple injuries.

Authors:  J Noble; C A Munro; V S Prasad; R Midha
Journal:  J Trauma       Date:  1998-07

6.  Pressure ulcers: prevention, evaluation, and management.

Authors:  Daniel Bluestein; Ashkan Javaheri
Journal:  Am Fam Physician       Date:  2008-11-15       Impact factor: 3.292

7.  Sensing pressure distribution on a lower-limb exoskeleton physical human-machine interface.

Authors:  Stefano Marco Maria De Rossi; Nicola Vitiello; Tommaso Lenzi; Renaud Ronsse; Bram Koopman; Alessandro Persichetti; Fabrizio Vecchi; Auke Jan Ijspeert; Herman van der Kooij; Maria Chiara Carrozza
Journal:  Sensors (Basel)       Date:  2010-12-28       Impact factor: 3.576

8.  Real-time strap pressure sensor system for powered exoskeletons.

Authors:  Jesús Tamez-Duque; Rebeca Cobian-Ugalde; Atilla Kilicarslan; Anusha Venkatakrishnan; Rogelio Soto; Jose Luis Contreras-Vidal
Journal:  Sensors (Basel)       Date:  2015-02-16       Impact factor: 3.576

9.  A flexible sensor technology for the distributed measurement of interaction pressure.

Authors:  Marco Donati; Nicola Vitiello; Stefano Marco Maria De Rossi; Tommaso Lenzi; Simona Crea; Alessandro Persichetti; Francesco Giovacchini; Bram Koopman; Janez Podobnik; Marko Munih; Maria Chiara Carrozza
Journal:  Sensors (Basel)       Date:  2013-01-15       Impact factor: 3.576

10.  A fuzzy controller for lower limb exoskeletons during sit-to-stand and stand-to-sit movement using wearable sensors.

Authors:  Sharif Muhammad Taslim Reza; Norhafizan Ahmad; Imtiaz Ahmed Choudhury; Raja Ariffin Raja Ghazilla
Journal:  Sensors (Basel)       Date:  2014-03-04       Impact factor: 3.576

View more
  1 in total

Review 1.  Characterization and Evaluation of Human-Exoskeleton Interaction Dynamics: A Review.

Authors:  Stefano Massardi; David Rodriguez-Cianca; David Pinto-Fernandez; Juan C Moreno; Matteo Lancini; Diego Torricelli
Journal:  Sensors (Basel)       Date:  2022-05-25       Impact factor: 3.847

  1 in total