Literature DB >> 28007371

Knee Kinematic and Clinical Outcomes Evolution Before, 3 Months, and 1 Year After Total Knee Arthroplasty.

Alice Bonnefoy-Mazure1, Stéphane Armand1, Yoshisama Sagawa2, Domizio Suvà3, Hermes Miozzari3, Katia Turcot4.   

Abstract

BACKGROUND: The aim of this study was to describe the evolution of kinematic and clinical outcomes of a large patient cohort with knee osteoarthritis from before surgery (V1) to 3 months (V2) and 1 year (V3) after a total knee arthroplasty (TKA).
METHODS: The patients were evaluated at each visit (118 patients at V1, 93 patients at V2, and 79 patients at V3) during a clinical gait analysis and were compared with a matched control group of healthy adults (CG). The kinematic parameters, the Western Ontario and MacMaster Osteoarthritis Index (WOMAC), quality of life, and patient satisfaction were assessed. Gait velocity and knee range of motion (ROM) as well as clinical parameters were compared at each visit with CG was based on the unpaired samples t-test. To determine changes in the data at baseline, 3 months, and 1 year after surgery in the patient groups, repeated-measure analysis of variance was conducted (P < .05). Pearson correlation was used to examine relationships between clinical and biomechanical outcomes.
RESULTS: One year after TKA (V3) compared to V1 and V2, the ROM of the operated knee during gait was significantly improved (V1: 44.2 ± 8.8° vs V3: 47.5 ± 7.1°, P < .001, and V2: 42.2 ± 9.3° vs V3: 47.5 ± 7.1°, P = .001), as was the gait velocity (V1: 1.0 ± 0.2 and V2: 1.1 ± 0.2 m/s vs V3: 1.3 ± 0.2 m/s, P < .001). The WOMAC and knee pain were significantly better 1 year after TKA. No strong relationships have been found between clinical parameters and knee kinematics.
CONCLUSION: This study showed that 1 year after TKA, patients exhibited improved gait velocity and ROM and experienced a significant decrease in the level of pain and an increased clinical score (although different from CG).
Copyright © 2016. Published by Elsevier Inc.

Entities:  

Keywords:  gait; knee kinematic; longitudinal study; osteoarthritis; total knee arthroplasty

Mesh:

Year:  2016        PMID: 28007371     DOI: 10.1016/j.arth.2016.03.050

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

Review 1.  Current applications of gait analysis after total knee arthroplasty: A scoping review.

Authors:  Neeraj Vij; Christian Leber; Kenneth Schmidt
Journal:  J Clin Orthop Trauma       Date:  2022-09-05

2.  Individual Gait Features Are Associated with Clinical Improvement After Total Knee Arthroplasty.

Authors:  Kathryn L Young-Shand; Michael J Dunbar; Janie L Astephen Wilson
Journal:  JB JS Open Access       Date:  2020-04-06

3.  Early Spatiotemporal Patterns and Knee Kinematics during Level Walking in Individuals following Total Knee Arthroplasty.

Authors:  Xubo Wu; Lixi Chu; Lianbo Xiao; Yong He; Shuyun Jiang; Songbin Yang; Yijie Liu
Journal:  J Healthc Eng       Date:  2017-07-31       Impact factor: 2.682

4.  Correlations between patient-perceived outcome and objectively-measured biomechanical change following Total Knee Replacement.

Authors:  P R Biggs; G M Whatling; C Wilson; C A Holt
Journal:  Gait Posture       Date:  2019-02-25       Impact factor: 2.840

5.  Intersegmental Coordination in Patients With Total Knee Arthroplasty During Walking.

Authors:  Yingpeng Wang; Shuyan Qie; Yingqi Li; Songhua Yan; Jizhou Zeng; Kuan Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-02-24

6.  Tibio-Femoral Contact Force Distribution of Knee Before and After Total Knee Arthroplasty: Combined Finite Element and Gait Analysis.

Authors:  Mingming Du; Jun Sun; Yancheng Liu; Yingpeng Wang; Songhua Yan; Jizhou Zeng; Kuan Zhang
Journal:  Orthop Surg       Date:  2022-06-29       Impact factor: 2.279

7.  Which osteoarthritic gait features recover following total knee replacement surgery?

Authors:  Paul Robert Biggs; Gemma Marie Whatling; Chris Wilson; Andrew John Metcalfe; Cathy Avril Holt
Journal:  PLoS One       Date:  2019-01-25       Impact factor: 3.240

8.  Mobile-bearing insert used with total knee arthroplasty does not rotate on the tibial tray during a squatting activity: a cross-sectional study.

Authors:  Kenji Hoshi; Goro Watanabe; Yasuo Kurose; Ryuji Tanaka; Jiro Fujii; Kazuyoshi Gamada
Journal:  J Orthop Surg Res       Date:  2020-03-20       Impact factor: 2.359

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.