Literature DB >> 28006684

An efficient ratiometric fluorescence sensor based on metal-organic frameworks and quantum dots for highly selective detection of 6-mercaptopurine.

Meng Jin1, Zhao-Li Mou1, Rui-Ling Zhang1, Si-Si Liang1, Zhi-Qi Zhang2.   

Abstract

The development of a simple and accurate quantitative method for the determination of 6-mercaptopurine (6-MP) is of great importance because of its serious side effects. Ratiometric fluorescence (RF) sensors are not subject to interference from environmental factors, and exhibit enhanced precision and accuracy. Therefore, a novel RF sensor for the selective detection of 6-MP was developed based on a dual-emission nanosensor. The nanosensor was fabricated by combining a blue-emission metal-organic framework (MOF) NH2-MIL-53(Al) (λem=425nm) with green-emission 3-mercaptopropionic acid-capped CdTe quantum dots (MPA-CdTe QDs) (λem=528nm) under a single excitation wavelength (335nm). Upon addition of 6-MP, the fluorescence of NH2-MIL-53(Al) in the nanohybrid was selectively quenched due to strong inner filter effects, while the fluorescence of the MPA-CdTe QDs was enhanced. The novel RF sensor exhibited higher selectivity towards 6-MP than CdTe QDs alone, and higher sensitivity than MOFs alone. 6-MP could be detected in the range of 0-50μM with a detection limit of 0.15μM (S/N=3). The developed sensor was applied for the determination of 6-MP in human urine samples and satisfactory results were obtained. Overall, a novel and efficient fluorescence-based method was developed for the detection of 6-MP in biosamples.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  6-Mercaptopurine; CdTe quantum dots; Inner filter effect; Metal-organic frameworks; Ratiometric fluorescence sensor

Mesh:

Substances:

Year:  2016        PMID: 28006684     DOI: 10.1016/j.bios.2016.12.022

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

1.  Fluorometric determination of copper(II) by using 3-aminophenylboronic acid-functionalized CdTe quantum dot probes.

Authors:  Huayu Xiong; Bei Wang; Wei Wen; Xiuhua Zhang; Shengfu Wang
Journal:  Mikrochim Acta       Date:  2019-05-31       Impact factor: 5.833

2.  Phosphate-triggered ratiometric fluoroimmunoassay based on nanobody-alkaline phosphatase fusion for sensitive detection of 1-naphthol for the exposure assessment of pesticide carbaryl.

Authors:  Zi-Jian Chen; Hui-Ling Wu; Yu-Dong Shen; Hong Wang; Yi-Feng Zhang; Bruce Hammock; Zhen-Feng Li; Lin Luo; Hong-Tao Lei; Zhen-Lin Xu
Journal:  J Hazard Mater       Date:  2021-10-02       Impact factor: 10.588

3.  Preparation of strongly fluorescent water-soluble dithiothreitol modified gold nanoclusters coated with carboxychitosan, and their application to fluorometric determination of the immunosuppressive 6-mercaptopurine.

Authors:  Hao-Hua Deng; Kai-Yuan Huang; Qiong-Qiong Zhuang; Quan-Quan Zhuang; Hua-Ping Peng; Yin-Huan Liu; Xing-Hua Xia; Wei Chen
Journal:  Mikrochim Acta       Date:  2018-08-03       Impact factor: 5.833

4.  Aspartic acid assisted one-step synthesis of stable CsPbX3@Asp-Cs4PbX6 by in situ growth in NH2-MIL-53 for ratiometric fluorescence detection of 4-bromophenoxybenzene.

Authors:  Xiaoyu Fang; Jianping Ye; Ding Duan; Xin Cai; Xinmin Guo; Kang Li
Journal:  Mikrochim Acta       Date:  2021-05-27       Impact factor: 5.833

5.  A water-stable lanthanide metal-organic framework for fluorimetric detection of ferric ions and tryptophan.

Authors:  Hani Nasser Abdelhamid; Antonio Bermejo-Gómez; Belén Martín-Matute; Xiaodong Zou
Journal:  Mikrochim Acta       Date:  2017-06-13       Impact factor: 5.833

6.  Two Highly Stable Luminescent Lead Phosphonates Based on Mixed Ligands: Highly Selective and Sensitive Sensing for Thymine Molecule and VO3 - Anion.

Authors:  Xiao-Ou Cai; Meng Sun; Yu-Jing Shao; Fang Liu; Qun-Li Liu; Yan-Yu Zhu; Zhen-Gang Sun; Da-Peng Dong; Jing Li
Journal:  ACS Omega       Date:  2018-12-03

7.  Porphyrin Molecules Decorated on Metal-Organic Frameworks for Multi-Functional Biomedical Applications.

Authors:  Navid Rabiee; Mohammad Rabiee; Soheil Sojdeh; Yousef Fatahi; Rassoul Dinarvand; Moein Safarkhani; Sepideh Ahmadi; Hossein Daneshgar; Fatemeh Radmanesh; Saeid Maghsoudi; Mojtaba Bagherzadeh; Rajender S Varma; Ebrahim Mostafavi
Journal:  Biomolecules       Date:  2021-11-17

8.  A Water-Stable 2-Fold Interpenetrating cds Net as a Bifunctional Fluorescence-Responsive Sensor for Selective Detection of Cr(III) and Cr(VI) Ions.

Authors:  Meng-Jung Tsai; Kuo-Shun Liao; Jing-Yun Wu
Journal:  Nanomaterials (Basel)       Date:  2022-01-03       Impact factor: 5.076

9.  A Cd(II) Luminescent Coordination Grid as a Multiresponsive Fluorescence Sensor for Cr(VI) Oxyanions and Cr(III), Fe(III), and Al(III) in Aqueous Medium.

Authors:  Kuo-Shun Liao; Meng-Jung Tsai; Li-Jen Hsu; Chih-Min Wang; Jing-Yun Wu
Journal:  Molecules       Date:  2021-11-24       Impact factor: 4.411

10.  A Ratiometric Fiber Optic Sensor Based on CdTe QDs Functionalized with Glutathione and Mercaptopropionic Acid for On-Site Monitoring of Antibiotic Ciprofloxacin in Aquaculture Water.

Authors:  Xiao-Lin Yuan; Xiao-Yi Wu; Miao He; Jia-Ping Lai; Hui Sun
Journal:  Nanomaterials (Basel)       Date:  2022-03-01       Impact factor: 5.076