Literature DB >> 28005433

Combined Special Capsular Tension Ring and Toric IOL Implantation for Management of Astigmatism and High Axial Myopia with Cataracts.

Yang Zhao1, Jiaxin Li2, Ke Yang1, Xiao Li1, Siquan Zhu1.   

Abstract

AIM: This study aimed to compare the effects of toric intraocular lens (IOL) implantation with a capsular tension ring and toric IOL implantation only in patients with axial myopic astigmatism who had undergone cataract surgery.
METHODS: Of 34 patients with axial myopia, 16 patients who had received IOL and capsular tension ring (CTR) implantation were included in the combined group and 18 patients who received toric IOL implantation only were included in the simple group. Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA) were evaluated by measuring subjective refraction, residual astigmatism, and the toric IOL axis six months post-surgery.
RESULTS: At six months postoperatively, the UCVA for the combined and simple groups was 4.6 ± 0.1 and 4.5 ± 0.2, respectively, a statistically significant difference (t = 3.531, P<0.05). The toric IOL in all of the cases was located in the capsular sac, but there were more cases with IOL rotation (12 eyes) in the simple group than in the combined group (4 eyes). The rotation angles were 20°~30° (one eye), 10°~20° (four eyes), and <10° (seven eyes) compared with 2°~5° (four eyes). The residual astigmatism was -0.50 ± 0.25 D in the combined group, not a significant difference from the predicted residual astigmatism (-0.35 ± 0.13 D). There was a significant difference in the simple group (-1.25 ± 0.33 D) when the predicted residual astigmatism was compared (-0.37 ± 0.11 D) (t = -9.511, P < 0.01).
CONCLUSIONS: In patients with axial myopic astigmatism, CTR can effectively increase the rotational stability of a toric IOL, achieving improvement in corneal astigmatism and visual acuity.

Entities:  

Keywords:  Astigmatism; capsular tension ring; rotation stability; toric intraocular lens; visual acuity

Mesh:

Year:  2016        PMID: 28005433     DOI: 10.1080/08820538.2016.1247181

Source DB:  PubMed          Journal:  Semin Ophthalmol        ISSN: 0882-0538            Impact factor:   1.975


  6 in total

1.  Association between axial length and toric intraocular lens rotation according to an online toric back-calculator.

Authors:  Jennifer L Patnaik; Malik Y Kahook; John P Berdahl; David R Hardten; Brandie D Wagner; Leonard K Seibold; Brent A Kramer
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

2.  Propensity-matched comparison of postoperative stability and visual outcomes of toric intraocular lens with or without a capsular tension ring and updated meta-analysis.

Authors:  Dongmei Ma; Xiaoyan Han; Zhixiang Hua; Jiying Shen; Limei Zhang; Tian Qiu; Jianfeng Luo; Lei Cai; Jin Yang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-10-06       Impact factor: 3.535

3.  Effect of capsular tension ring implantation on capsular stability after phacoemulsification in patients with weak zonules: a randomized controlled trial. CTR implantation in cataract patients with weak zonules.

Authors:  Shangfei Yang; Hui Jiang; Kailai Nie; Liwen Feng; Wei Fan
Journal:  BMC Ophthalmol       Date:  2021-01-07       Impact factor: 2.209

4.  How to Manage the Cortex After CTR Insertion.

Authors:  Kazuki Matsuura; Teruyuki Miyoshi; Hironori Yoshida; Takahiro Shimowake
Journal:  Clin Ophthalmol       Date:  2022-04-08

5.  Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring.

Authors:  Anju Rastogi; Samreen Khanam; Yashpal Goel; Prolima Thacker; Prateek Kumar
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

6.  Effects of capsular tension ring on surgical outcomes of premium intraocular lens in patients with suspected zonular weakness.

Authors:  Teruyuki Miyoshi; Shuhei Fujie; Hironori Yoshida; Hiroshi Iwamoto; Hideki Tsukamoto; Tetsuro Oshika
Journal:  PLoS One       Date:  2020-02-24       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.