Literature DB >> 28004262

Diagnostic accuracy of tubomanometry R value in detecting the Eustachian tube pressure equalizing function.

Cuneyt M Alper1,2, Miriam S Teixeira3, Jeehong H Kim4, J Douglas Swarts3.   

Abstract

Tubomanometry is a relatively novel Eustachian tube (ET) function testing method. A number of recent studies have utilized the R value of Tubomanometry as the main objective measure in reporting their outcome in balloon dilation of ET. There is, however, a lack of evidence concerning the reliability or validity of Tubomanometry measurements. The objectives of this study are to determine the accuracy of Tubomanometry for detecting ET opening as compared to tympanometry and determine its usefulness as a measure of ET function. Healthy subjects between ages 8 and 76 years with an intact tympanic membrane and no middle ear (ME) effusion were prospectively tested. Primary outcomes were the ET opening as determined by the Tubomanometry R value and the increase in ME pressure with tympanometry-measured in relation to a swallow at a nasopharyngeal pressure of 300 daPa. The accuracy of the tubomanometry R value for identifying a successful ET opening was made in reference to the change of ME pressure. A total of 280 measurements were available from 258 ears in 137 subjects. The presence of tubomanometry R value showed high sensitivity of detecting ET opening for the criteria of >5 daPa ME pressure increase (187/202) but low specificity for detecting ET non-opening (34/78). The R value criterion described in the original manuscripts on Tubomanometry is sensitive but not specific for ET opening. The need for validation of the tubomanometry test obviates its use as the main objective outcome measure for the balloon dilation of ET procedure.

Entities:  

Keywords:  Balloon dilation; Eustachian tube dysfunction; Tubomanometry

Mesh:

Year:  2016        PMID: 28004262     DOI: 10.1007/s00405-016-4430-6

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  17 in total

1.  Tubomanometry. Values in ears with traumatic and chronic perforations.

Authors:  A Mink; M Bauer
Journal:  Clin Otolaryngol Allied Sci       Date:  1993-08

2.  First results of Endonasal dilatation of the Eustachian tube (EET) in patients with chronic obstructive tube dysfunction.

Authors:  Carsten V Dalchow; M Loewenthal; N Kappo; F Jenckel; B B Loerincz; R Knecht
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-03-19       Impact factor: 2.503

3.  Evaluation of tubomanometry as a routine diagnostic tool for chronic obstructive Eustachian tube dysfunction.

Authors:  S Schröder; M Lehmann; D Korbmacher; O Sauzet; H Sudhoff; J Ebmeyer
Journal:  Clin Otolaryngol       Date:  2015-12       Impact factor: 2.597

4.  Function of the Eustachian tube related to surgical management of acquired aural cholesteatoma in children.

Authors:  C D Bluestone; E I Cantekin; Q C Beery; S E Stool
Journal:  Laryngoscope       Date:  1978-07       Impact factor: 3.325

5.  Balloon Eustachian tuboplasty: a retrospective cohort study.

Authors:  S Schröder; M Lehmann; J Ebmeyer; T Upile; H Sudhoff
Journal:  Clin Otolaryngol       Date:  2015-12       Impact factor: 2.597

6.  Balloon dilation of the Eustachian tube: early outcome analysis.

Authors:  Nicolas Gürtler; Alexander Husner; Honegger Flurin
Journal:  Otol Neurotol       Date:  2015-03       Impact factor: 2.311

7.  Prognostic value of eustachian tube function in pediatric tympanoplasty.

Authors:  S C Manning; E I Cantekin; M A Kenna; C D Bluestone
Journal:  Laryngoscope       Date:  1987-09       Impact factor: 3.325

8.  [Middle ear barotraumas due to rhinopharyngeal scar tissue: tubomanometry diagnostic and therapeutic contribution].

Authors:  M Collin; M Coulange; A Devèze; M Montava; D Estève; J P Lavieille
Journal:  Rev Laryngol Otol Rhinol (Bord)       Date:  2012

9.  Eustachian tube function related to the results of tympanoplasty in children.

Authors:  C D Bluestone; E I Cantekin; G S Douglas
Journal:  Laryngoscope       Date:  1979-03       Impact factor: 3.325

10.  A novel diagnostic tool for chronic obstructive eustachian tube dysfunction—the eustachian tube score.

Authors:  Stefanie Schröder; Martin Lehmann; Odile Sauzet; Jörg Ebmeyer; Holger Sudhoff
Journal:  Laryngoscope       Date:  2014-09-12       Impact factor: 3.325

View more
  5 in total

1.  Accuracy of the ETDQ-7 for Identifying Persons with Eustachian Tube Dysfunction.

Authors:  Miriam S Teixeira; J Douglas Swarts; Cuneyt M Alper
Journal:  Otolaryngol Head Neck Surg       Date:  2017-09-26       Impact factor: 3.497

2.  Association Between Eustachian Tube Dysfunction Questionnaire-7 Scores and Eustachian Tube Function Test Results in Symptomatic Patients With a Normal Drum.

Authors:  Seojin Moon; Yujin Lee; Jinsei Jung; In Seok Moon; Seong Hoon Bae
Journal:  J Audiol Otol       Date:  2022-05-12

Review 3.  Clinical value of the Eustachian Tube Function Scoring System T-ETDQ: a prospective diagnostic study.

Authors:  Hongyi Lu; Jun Su; Wanlei Chi; Ting Zou; Mingqiang Yu; Kang Wang
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-09-29       Impact factor: 3.236

4.  Eustachian tube dysfunction in patients with house dust mite-allergic rhinitis.

Authors:  Yun Ma; Maojin Liang; Peng Tian; Xiang Liu; Hua Dang; Qiujian Chen; Hua Zou; Yiqing Zheng
Journal:  Clin Transl Allergy       Date:  2020-07-15       Impact factor: 5.871

Review 5.  Advances in Eustachian tube function testing.

Authors:  Matthew E Smith; Manohar L Bance; James R Tysome
Journal:  World J Otorhinolaryngol Head Neck Surg       Date:  2019-10-11
  5 in total