BACKGROUND: The Flexion ABduction External Rotation (FABER) test is typically used as a provocation special test, but has also been used as a measurement of combined hip range of motion (ROM). It is thought that limited ROM with this measurement may be indicative of hip pathology. To date, normative data, reliability, and minimal detectable change (MDC) of such measurements have not been established. PURPOSE: To determine normative FABER height, assess inter- and intra-rater reliability and MDC for FABER, and compare traditional FABER measurements to methods which account for differences in thigh length. STUDY DESIGN: Descriptive laboratory reliability study. METHODS: Nineteen healthy participants without low back, hip, or knee pain in the preceding three months were recruited. Measurements were performed during two sessions (three to seven days between sessions) by three clinicians. FABER height and thigh length measurements were performed. Thigh length normalized FABER range of motion (ROM) and side-to-side FABER ROM symmetry were calculated. One tester also measured FABER with a digital inclinometer. Inter- and intra-rater reliability were calculated using interclass correlation coefficients (ICC) and mean MDC values were calculated. RESULTS: Mean values for FABER height and normalized FABER ROM were 12.4 ± 2.8 cm and 0.30 ± 0.07, respectively. Inter-rater reliability for FABER and normalized FABER were good (ICC 0.67-0.68) and between session intra-rater reliability were good to excellent (ICC 0.76-0.86). Mean FABER and normalized FABER ROM MDC were 3.7 cm and 0.04, respectively. Mean FABER ROM symmetry was 2.0 ± 0.9 cm with poor inter-rater reliability (ICC 0.20), poor to good intra-rater reliability (ICC 0.38-0.66), and mean MDC of 4.0 cm. FABER measured with a ruler, normalized FABER ROM, and inclinometry all resulted in excellent intra-rater reliability, with the highest ICC being demonstrated for inclinometry (ICC 0.86, 0.86, and 0.91). CONCLUSIONS: Overall, FABER measurements were reliable, whether normalized to thigh length or not. Furthermore, use of inclinometry may increase reliability. Reliability was poor to good when assessing symmetry between limbs. LEVEL OF EVIDENCE: Level 3.
BACKGROUND: The Flexion ABduction External Rotation (FABER) test is typically used as a provocation special test, but has also been used as a measurement of combined hip range of motion (ROM). It is thought that limited ROM with this measurement may be indicative of hip pathology. To date, normative data, reliability, and minimal detectable change (MDC) of such measurements have not been established. PURPOSE: To determine normative FABER height, assess inter- and intra-rater reliability and MDC for FABER, and compare traditional FABER measurements to methods which account for differences in thigh length. STUDY DESIGN: Descriptive laboratory reliability study. METHODS: Nineteen healthy participants without low back, hip, or knee pain in the preceding three months were recruited. Measurements were performed during two sessions (three to seven days between sessions) by three clinicians. FABER height and thigh length measurements were performed. Thigh length normalized FABER range of motion (ROM) and side-to-side FABER ROM symmetry were calculated. One tester also measured FABER with a digital inclinometer. Inter- and intra-rater reliability were calculated using interclass correlation coefficients (ICC) and mean MDC values were calculated. RESULTS: Mean values for FABER height and normalized FABER ROM were 12.4 ± 2.8 cm and 0.30 ± 0.07, respectively. Inter-rater reliability for FABER and normalized FABER were good (ICC 0.67-0.68) and between session intra-rater reliability were good to excellent (ICC 0.76-0.86). Mean FABER and normalized FABER ROM MDC were 3.7 cm and 0.04, respectively. Mean FABER ROM symmetry was 2.0 ± 0.9 cm with poor inter-rater reliability (ICC 0.20), poor to good intra-rater reliability (ICC 0.38-0.66), and mean MDC of 4.0 cm. FABER measured with a ruler, normalized FABER ROM, and inclinometry all resulted in excellent intra-rater reliability, with the highest ICC being demonstrated for inclinometry (ICC 0.86, 0.86, and 0.91). CONCLUSIONS: Overall, FABER measurements were reliable, whether normalized to thigh length or not. Furthermore, use of inclinometry may increase reliability. Reliability was poor to good when assessing symmetry between limbs. LEVEL OF EVIDENCE: Level 3.
Entities:
Keywords:
FABER; femoroacetabular impingement; hip; range of motion; reliability
Authors: Charles Ratzlaff; Jacqueline Simatovic; Hubert Wong; Linda Li; Allison Ezzat; Dolores Langford; John M Esdaile; Carol Kennedy; Patrick Embley; Darryl Caves; Trish Hopkins; Jolanda Cibere Journal: Arthritis Care Res (Hoboken) Date: 2013-10 Impact factor: 4.794
Authors: Ashley L Kapron; Stephen K Aoki; Christopher L Peters; Steve A Maas; Michael J Bey; Roger Zauel; Andrew E Anderson Journal: J Appl Biomech Date: 2014-02-25 Impact factor: 1.833
Authors: Marc J Philippon; R Brian Maxwell; Todd L Johnston; Mara Schenker; Karen K Briggs Journal: Knee Surg Sports Traumatol Arthrosc Date: 2007-05-12 Impact factor: 4.342
Authors: Bruce Mitchell; Paul McCrory; Peter Brukner; John O'Donnell; Emma Colson; Robert Howells Journal: Clin J Sport Med Date: 2003-05 Impact factor: 3.638
Authors: Ivan Urits; Aaron Burshtein; Medha Sharma; Lauren Testa; Peter A Gold; Vwaire Orhurhu; Omar Viswanath; Mark R Jones; Moises A Sidransky; Boris Spektor; Alan D Kaye Journal: Curr Pain Headache Rep Date: 2019-03-11
Authors: David Metcalfe; Daniel C Perry; Henry A Claireaux; David L Simel; Cheryl K Zogg; Matthew L Costa Journal: JAMA Date: 2019-12-17 Impact factor: 56.272
Authors: Till D Lerch; Sébastien Zwingelstein; Florian Schmaranzer; Adam Boschung; Markus S Hanke; Inga A S Todorski; Simon D Steppacher; Nicolas Gerber; Guodong Zeng; Klaus A Siebenrock; Moritz Tannast Journal: Orthop J Sports Med Date: 2021-05-28
Authors: K C Geoffrey Ng; Hadi El Daou; Marcus J K Bankes; Ferdinando Rodriguez Y Baena; Jonathan R T Jeffers Journal: Am J Sports Med Date: 2018-12-31 Impact factor: 6.202