Ahmed Mohammed Al-Madawy1, Mohamed Mahmoud Abou Elatta1, Mostafa Mahmoud Hasanin2, Ashraf Abd El-Kader Al-Nahal2.
Abstract
Objective This study aims to evaluate the use of minilocked plates in the treatment of the metacarpal fractures. Method A total of 30 patients of metacarpal fractures were treated by minilocked plates. Results Union was achieved in all patients. There were 27 (90%) patients having satisfactory results (excellent and good results) and 3 patients (10%) had poor results. Conclusion The use of minilocked plate is recommended for fixation of periarticular, comminuted, and osteoporotic metacarpal fractures that offer rigid fixation early mobilization, decreases the incidence of joints stiffness, and tendon adherence which maximized the hand function.Entities:
Keywords: locked plates; metacarpal fracture; miniplate
Year: 2016 PMID: 27999459 PMCID: PMC5167616 DOI: 10.1055/s-0036-1593730