Literature DB >> 27998665

A study to evaluate the reliability of using two-dimensional photographs, three-dimensional images, and stereoscopic projected three-dimensional images for patient assessment.

S Zhu1, Y Yang1, B Khambay2.   

Abstract

Clinicians are accustomed to viewing conventional two-dimensional (2D) photographs and assume that viewing three-dimensional (3D) images is similar. Facial images captured in 3D are not viewed in true 3D; this may alter clinical judgement. The aim of this study was to evaluate the reliability of using conventional photographs, 3D images, and stereoscopic projected 3D images to rate the severity of the deformity in pre-surgical class III patients. Forty adult patients were recruited. Eight raters assessed facial height, symmetry, and profile using the three different viewing media and a 100-mm visual analogue scale (VAS), and appraised the most informative viewing medium. Inter-rater consistency was above good for all three media. Intra-rater reliability was not significantly different for rating facial height using 2D (P=0.704), symmetry using 3D (P=0.056), and profile using projected 3D (P=0.749). Using projected 3D for rating profile and symmetry resulted in significantly lower median VAS scores than either 3D or 2D images (all P<0.05). For 75% of the raters, stereoscopic 3D projection was the preferred method for rating. The reliability of assessing specific characteristics was dependent on the viewing medium. Clinicians should be aware that the visual information provided when viewing 3D images is not the same as when viewing 2D photographs, especially for facial depth, and this may change the clinical impression. Crown
Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  class III; facial deformity; orthognathic; photographs; projected; stereoscopic; three-dimensional

Mesh:

Year:  2016        PMID: 27998665     DOI: 10.1016/j.ijom.2016.11.011

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  3 in total

1.  Evaluation of two stereophotogrametry software for 3D reconstruction of virtual facial models.

Authors:  Lorena Basilio Chaves; Taliane Lima Barbosa; Caroline Pelagio Maués Casagrande; David Silveira Alencar; Jonas Capelli; Felipe de Assis Ribeiro Carvalho
Journal:  Dental Press J Orthod       Date:  2022-07-04

2.  Usefulness and capability of three-dimensional, full high-definition movies for surgical education.

Authors:  M Takano; K Kasahara; K Sugahara; A Watanabe; S Yoshida; T Shibahara
Journal:  Maxillofac Plast Reconstr Surg       Date:  2017-04-05

3.  Evaluation of the relationship between malar projection and lower facial convexity in terms of perceived attractiveness in 3-dimensional reconstructed images.

Authors:  Hon Kwan Woo; Deepal Haresh Ajmera; Pradeep Singh; Kar Yan Li; Michael Marc Bornstein; Kwan Lok Tse; Yanqi Yang; Min Gu
Journal:  Head Face Med       Date:  2020-04-28       Impact factor: 2.151

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.