Crestal Bone Loss Around Adjacent Dental Implants Restored with Splinted and Nonsplinted Fixed Restorations: A Systematic Literature Review.

Mohammad D Al Amri1, Sergio Varela Kellesarian2.   

Abstract

PURPOSE: The aim of this systematic review was to compare the crestal bone loss around splinted and nonsplinted adjacent implants.
MATERIALS AND METHODS: To address the focused question, "Is crestal bone loss around adjacent implants different with splinted from that with nonsplinted restorations?," indexed databases were searched from 1965 up to and including May 2016 using various combinations of the following keywords: "implant," "splinted," "nonsplinted," "unsplinted," "connected," "unconnected," "nonconnected," and "bone loss." Letters to the editor, commentaries, historic reviews, case reports, case series, animal studies, and studies on full-arch rehabilitation were excluded.
RESULTS: Six studies were included with titanium implants ranging from 114 to 1187 implants. All studies had nonsplinted and splinted restorations that ranged from 20 to 234 restorations and from 60 to 970 restorations, respectively. In all the studies, the follow-up period after the restoration placement ranged between 1 and 22 years, with a mean follow-up ranging between 3 and 10.18 ± 3.18 years. In all studies, the mean crestal bone loss for implants restored with nonsplinted restorations ranged between 0.30 ± 0.65 and 1.3 ± 0.2 mm, whereas the mean crestal bone loss for implants restored with splinted restorations ranged between 0.50 ± 0.8 and 1.22 ± 0.95 mm.
CONCLUSION: Within the limitations of this review it is concluded that adjacent implants restored with splinted and nonsplinted fixed restorations did not exhibit a difference in crestal bone loss. The evidence from this systematic review suggests further investigation.
© 2016 by the American College of Prosthodontists.

Entities:  

Keywords:  Crestal bone loss; adjacent implants; connected; fixed restorations; splinted

Mesh:

Substances:

Year:  2016        PMID: 27996179     DOI: 10.1111/jopr.12556

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  High-Frequency Ultrasound for Assessment of Peri-Implant Bone Thickness.

Authors:  Juliana Marotti; Sarah Neuhaus; Daniel Habor; Lauren Bohner; Stefan Heger; Klaus Radermacher; Stefan Wolfart
Journal:  J Clin Med       Date:  2019-09-25       Impact factor: 4.241

2.  The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants.

Authors:  Nasreen Hamudi; Eitan Barnea; Evgeny Weinberg; Amir Laviv; Eitan Mijiritsky; Shlomo Matalon; Liat Chaushu; Roni Kolerman
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

3.  The reduction of vertical food impact using adjacent surface retaining zirconium crowns preparation technique: a 1-year follow-up prospective clinical study.

Authors:  Qun Lu; Lili Wang
Journal:  Ann Transl Med       Date:  2020-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.