Literature DB >> 2799444

Percutaneous retrieval of a broken Lunderquist guidewire from the pelvicalyceal system.

D R Bezirdjian1, J Tisnado, S R Cho.   

Abstract

The stiff Lunderquist guidewire may occasionally be needed during percutaneous insertion of a nephrostomy catheter, especially in patients with a large amount of subcutaneous fat or with a hard renal capsule. This wire may fracture at the junction of its stiff portion with the flexible tip. We have reported such an occurrence, in which an operative procedure was avoided by successful percutaneous retrieval of the broken wire tip, using the loop-snare technique.

Entities:  

Mesh:

Year:  1989        PMID: 2799444     DOI: 10.1097/00007611-198910000-00017

Source DB:  PubMed          Journal:  South Med J        ISSN: 0038-4348            Impact factor:   0.954


  1 in total

1.  Endourological treatment of foreign bodies in the urinary system.

Authors:  Erdal Alkan; M Murad Basar
Journal:  JSLS       Date:  2014 Jul-Sep       Impact factor: 2.172

  1 in total