Literature DB >> 27993752

Clinical outcomes of bioresorbable versus durable polymer-coated everolimus-eluting stents in real-world complex patients.

Marco G Mennuni1, Giulio G Stefanini, Paolo A Pagnotta, Elton Pllaha, Marco Araco, Omar A Meelu, Federica Turati, Bernhard Reimers, Gennaro Sardella, Patrizia Presbitero.   

Abstract

AIMS: The aim of this study was to evaluate the safety and efficacy profile of new-generation, SYNERGY everolimus-eluting stents (S-EES) as compared to XIENCE everolimus-eluting stents (X-EES) with a durable polymer coating in "complex patients". METHODS AND
RESULTS: We included 2,001 consecutive patients treated with S-EES (n=400) or X-EES (n=1,601) at two Italian centres between May 2013 and May 2015. We used propensity score matching to obtain two cohorts of patients with similar baseline risk profiles. Patients were stratified according to baseline complexity based on the EVOLVE II trial exclusion criteria. The primary outcome was major adverse cardiac events (MACE), defined as the composite of all-cause death, myocardial infarction (MI), and target lesion revascularisation (TLR), at one year. Among 391 matched pairs of patients treated with S-EES or X-EES, we identified 253 (63%) as complex. At one-year follow-up, among "complex" patients, MACE rates did not differ between the S-EES and X-EES groups (9.9% vs. 9.5%, p=0.830, HR 1.04, CI: 0.72-1.48). Similarly, death, MI, and TLR, stratified for complexity, were comparable between S-EES and X-EES treated patients at one year. Of note, no definite ST was observed in either the S-EES or the X-EES cohort.
CONCLUSIONS: New-generation S-EES with a bioresorbable polymer coating appear to be safe and effective irrespective of patient complexity as compared to X-EES.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 27993752     DOI: 10.4244/EIJ-D-16-00276

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  1 in total

1.  Comparison of bioresorbable vs durable polymer drug-eluting stents in unprotected left main (from the RAIN-CARDIOGROUP VII Study).

Authors:  Mario Iannaccone; Umberto Barbero; Michele De Benedictis; Yoichi Imori; Giorgio Quadri; Daniela Trabattoni; Nicola Ryan; Giuseppe Venuti; Andrea Montabone; Wojciech Wojakowski; Andrea Rognoni; Gerard Helft; Radoslaw Parma; Leonardo De Luca; Michele Autelli; Giacomo Boccuzzi; Alessio Mattesini; Christian Templin; Enrico Cerrato; Wojciech Wańha; Grzegorz Smolka; Zenon Huczek; Francesco Tomassini; Bernardo Cortese; Davide Capodanno; Alaide Chieffo; Ivan Nuñez-Gil; Sebastiano Gili; Antonia Bassignana; Carlo di Mario; Baldassarre Doronzo; Pierluigi Omedè; Maurizio D'Amico; Delio Tedeschi; Ferdinando Varbella; Thomas Luscher; Imad Sheiban; Javier Escaned; Mauro Rinaldi; Fabrizio D'Ascenzo
Journal:  BMC Cardiovasc Disord       Date:  2020-05-15       Impact factor: 2.298

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.