Literature DB >> 27988181

Incidence of Adverse Reactions to Metal Debris From 28-mm Metal-on-Metal Total Hip Arthroplasties With Minimum 10 Years of Follow-Up: Clinical, Laboratory, and Ultrasound Assessment of 44 Cases.

Béchir Ayoub1, Sophie Putman1, Pierre Cholewinski1, Amandine Paris2, Henri Migaud1, Julien Girard3.   

Abstract

BACKGROUND: Total hip arthroplasty with metal-on-metal (MoM) bearings has been suspected to cause adverse reactions to metal debris (ARMD), with the incidence varying greatly by implant type and patient gender. The prevalence of ARMD from small-diameter MoM bearings in women is unknown, especially after 10 years of follow-up (FU).
METHODS: Cementless 28-mm MoM total hip arthroplasty bearings (Metasul) were implanted consecutively in 42 active women between 1996 and 2002. They were reviewed after a minimum of 10 years' FU with clinical, laboratory, radiological, and ultrasound assessments.
RESULTS: Mean FU was 15.9 years (range, 13-18). The mean Postel-Merle d'Aubigné and Oxford scores were 16.9 (range, 13-18) and 15.1 (range, 12-24), respectively, at FU. Mean cup inclination angle was 46.3° (range, 35°-57°). No femoral osteolysis was detected, but limited acetabular osteolysis (11%) over the screw holes occurred in 5 cases. No liquid or solid synovial reactions or ARMD were apparent on ultrasound, even in the 5 cases of pelvic osteolysis. Mean chromium levels were 1.32 μg/L (range, 0.1-7.9) and cobalt levels were 1.85 μg/L (range, 0.35-13.6). Cobalt was >3 μg/L in only 3 cases. The 15.9-year survivorship was 95% (range, 94.1%-98.9%).
CONCLUSION: Reliable results were obtained with 28-mm MoM bearings, notably in young, active patients. This implant configuration requires very accurate positioning. No ARMD was seen in this group at 16 years' FU.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  28-mm metal-on-metal; adverse metal reaction; hip; long term outcomes; primary arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27988181     DOI: 10.1016/j.arth.2016.11.013

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  Serum cobalt concentrations remain at low levels at a minimum of 20 years following metal-on-metal total hip arthroplasty.

Authors:  Wenzel Waldstein; Ulrich Koller; Bernhard Springer; Paul Kolbitsch; Wolfram Brodner; Reinhard Windhager; Richard Lass
Journal:  Bone Joint Res       Date:  2020-05-16       Impact factor: 5.853

2.  Long-Term Results of a Second-Generation, Small-Diameter, Metal-On-Metal Bearing in Primary Total Hip Arthroplasty at 14-year Follow-Up.

Authors:  Tobias Reiner; Matthias C Klotz; Kirsten Seelmann; Fabian Hertzsch; Moritz M Innmann; Marcus R Streit; Timo A Nees; Babak Moradi; Christian Merle; Jan Philippe Kretzer; Tobias Gotterbarm
Journal:  Materials (Basel)       Date:  2020-01-24       Impact factor: 3.623

3.  Minimum 15-year results of metasul 28-mm metal-on-metal total hip arthroplasty in patients younger than 50 years of age.

Authors:  Sheng-Yu Jin; Jing-Yao Jin; Joon-Kyoo Kang; Taek-Rim Yoon; Kyung-Soon Park
Journal:  J Orthop Surg Res       Date:  2021-03-25       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.