Literature DB >> 27987393

Renewal of an old European Pharmacopoeia method for Terazosin using modeling with mass spectrometric peak tracking.

Róbert Kormány1, Imre Molnár2, Jenő Fekete3.   

Abstract

An older method for terazosin was reworked in order to reduce the analysis time from 90min (2×45min) to below 5min. The method in European Pharmacopoeia (Ph.Eur.) investigates the specified impurities separately. The reason of the different methods is that the retention of two impurities is not adequate in reversed phase, not even with 100% water. Therefore ion-pair-chromatography has to be applied and since that two impurities absorb at low UV-wavelength they had to be analyzed by different method than the other specified impurities. In our new method we could improve the retention with pH elevation using a new type of stationary phases available for high pH applications. Also a detection wavelength could be selected that is appropriate for the detection and quantification of all impurities. The method development is the bottleneck of liquid chromatography even today, when more and more fast chromatographic systems are used. Expert knowledge with intelligent programs is available to reduce the time of method development and offer extra information about the robustness of the separation. Design of Experiments (DoE) for simultaneous optimization of gradient time (tG), temperature (T) and ternary eluent composition (tC) requires 12 experiments. A good alternative way to identify a certain peak in different chromatograms is the molecular mass of the compound, due to its high specificity. Liquid Chromatography-Mass Spectrometry (LC-MS) is now a routine technique and increasingly available in laboratories. In our experiment for the resolution- and retention modeling the DryLab4 method development software (Version 4.2) was used. In recent versions of the software the use of (m/z)-MS-data is possible along the UV-peak-area-tracking technology. The modelled and measured chromatograms showed excellent correlations. The average retention time deviations were ca. 0.5s and there was no difference between the predicted and measured Rs,crit -values.
Copyright © 2016. Published by Elsevier B.V.

Entities:  

Keywords:  Design of experiments; DryLab; QDa detector; Quality by design; Terazosin; UHPLC

Mesh:

Substances:

Year:  2016        PMID: 27987393     DOI: 10.1016/j.jpba.2016.11.050

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  3 in total

1.  A Biosensor-Based Quantitative Analysis System of Major Active Ingredients in Lonicera japonica Thunb. Using UPLC-QDa and Chemometric Analysis.

Authors:  Lin Yang; Hai Jiang; Xudong Xing; Meiling Yan; Xinyue Guo; Wenjing Man; Ajiao Hou; Liu Yang
Journal:  Molecules       Date:  2019-05-08       Impact factor: 4.411

2.  Developing an Improved UHPLC Method for Efficient Determination of European Pharmacopeia Process-Related Impurities in Ropinirole Hydrochloride Using Analytical Quality by Design Principles.

Authors:  Tim Tome; Aleš Obreza; Zdenko Časar
Journal:  Molecules       Date:  2020-06-10       Impact factor: 4.411

3.  In-Silico UHPLC Method Optimization for Aglycones in the Herbal Laxatives Aloe barbadensis Mill., Cassia angustifolia Vahl Pods, Rhamnus frangula L. Bark, Rhamnus purshianus DC. Bark, and Rheum palmatum L. Roots.

Authors:  Nadja Meier; Beat Meier; Samuel Peter; Evelyn Wolfram
Journal:  Molecules       Date:  2017-10-27       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.