Literature DB >> 27984266

Unintentional Epinephrine Auto-injector Injuries: A National Poison Center Observational Study.

Marco Anshien1, S Rutherfoord Rose2,3, Brandon K Wills2,3.   

Abstract

BACKGROUND: Epinephrine is the only first-line therapeutic agent used to treat life-threatening anaphylaxis. Epinephrine auto-injectors are commonly carried by patients at risk for anaphylaxis, and reported cases of unintentional auto-injector injury have increased over the last decade. Modifications of existing designs and release of a new style of auto-injector are intended to reduce epinephrine auto-injector misuse. STUDY QUESTION: The aim of the study was to characterize reported cases of unintentional epinephrine auto-injector exposures from 2013 to 2014 and compare demographics, auto-injector model, and anatomical site of such exposures.
METHODS: The American Association of Poison Control Center's National Poison Data System was searched from January 1, 2013, to December 31, 2014, for cases of unintentional epinephrine auto-injector exposures. Anatomical site data were obtained from all cases reported to the Virginia Poison Center and participating regional poison center for Auvi-Q cases.
RESULTS: A total of 6806 cases of unintentional epinephrine auto-injector exposures were reported to US Poison Centers in 2013 and 2014. Of these cases, 3933 occurred with EpiPen, 2829 with EpiPen Jr, 44 with Auvi-Q, and no case reported of Adrenaclick. The most common site of unintentional injection for traditional epinephrine auto-injectors was the digit or thumb, with 58% of cases for EpiPen and 39% of cases with EpiPen Jr. With Auvi-Q, the most common site was the leg (78% of cases).
CONCLUSIONS: The number of unintentional epinephrine auto-injector cases reported to American Poison Centers in 2013-2014 has increased compared with previous data. Most EpiPen exposures were in the digits, whereas Auvi-Q was most frequently in the leg. Because of the limitations of Poison Center data, more research is needed to identify incidence of unintentional exposures and the effectiveness of epinephrine auto-injector redesign.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 27984266     DOI: 10.1097/MJT.0000000000000541

Source DB:  PubMed          Journal:  Am J Ther        ISSN: 1075-2765            Impact factor:   2.688


  1 in total

1.  Unintentional Epinephrine Auto-Injector Maxillofacial Injury in a Pediatric Patient.

Authors:  Jason David; Jerad Eldred; David Raper
Journal:  Clin Pract Cases Emerg Med       Date:  2022-02
  1 in total