Literature DB >> 27984249

Predicting Fluid Responsiveness in Acute Liver Failure: A Prospective Study.

Vinod Kumar Audimoolam1, Mark J W McPhail, Chris Willars, William Bernal, Julia A Wendon, Maurizio Cecconi, Georg Auzinger.   

Abstract

BACKGROUND: The profound hemodynamic changes seen in acute liver failure (ALF) resemble the hyperdynamic state found in the later stages of septic shock. Vasopressor support frequently is required after initial volume therapy. Markers of preload dependency have not been studied in this patient group. Dynamic maneuvers such as passive leg raising or end-expiratory hold, which have shown good predictive accuracy in a general intensive care unit population, cannot be considered safe in this cohort because of the concerns of intracranial hypertension.
METHODS: Mechanically ventilated patients with ALF admitted to a tertiary specialist intensive care unit in shock and multiorgan failure were enrolled. Markers of fluid responsiveness derived from transpulmonary thermodilution, pulse contour analysis, and echocardiography were compared between responders (cardiac index ≥15%) and nonresponders to a colloid fluid challenge (5 mL/kg predicted body weight). The ability to predict fluid responsiveness of stroke volume variation, pulse pressure variation (PPV), and respiratory change in peak (delta V peak) left ventricular outflow tract velocity for preload dependency were analyzed.
RESULTS: Thirty-five patients (mean ± SD age, 38 [14] years, 13 male, 22 female]) were assessed after a single fluid challenge. Ten patients (29%) were fluid responders. Changes in cardiac index and stroke volume index in the cohort of 35 patients were correlated (R = 0.726 [99% confidence interval, 0.401-0.910]; P < .001). PPV predicted fluid responsiveness (area under the receiver operating characteristic curve [AUROC], 0.752 [95% confidence interval, 0.565-0.889]; P = .005; cutoff >9%). The AUROC for stroke volume variation was 0.678 ([95% confidence interval, 0.499-0.825]; P = .084; cutoff >11%). The AUROC for [delta] V peak before fluid bolus was 0.637 (95% confidence interval, 0.413-0.825; P = .322).
CONCLUSIONS: PPV based on pulse contour analysis predicted fluid responsiveness in ALF.

Entities:  

Mesh:

Year:  2017        PMID: 27984249     DOI: 10.1213/ANE.0000000000001585

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

Review 1.  Indian National Association for the Study of Liver Consensus Statement on Acute Liver Failure (Part-2): Management of Acute Liver Failure.

Authors:  Anil C Anand; Bhaskar Nandi; Subrat K Acharya; Anil Arora; Sethu Babu; Yogesh Batra; Yogesh K Chawla; Abhijit Chowdhury; Ashok Chaoudhuri; Eapen C Eapen; Harshad Devarbhavi; Radha K Dhiman; Siddhartha Datta Gupta; Ajay Duseja; Dinesh Jothimani; Dharmesh Kapoor; Premashish Kar; Mohamad S Khuroo; Ashish Kumar; Kaushal Madan; Bipadabhanjan Mallick; Rakhi Maiwall; Neelam Mohan; Aabha Nagral; Preetam Nath; Sarat C Panigrahi; Ankush Pawar; Cyriac A Philips; Dibyalochan Prahraj; Pankaj Puri; Amit Rastogi; Vivek A Saraswat; Sanjiv Saigal; Akash Shukla; Shivaram P Singh; Thomas Verghese; Manav Wadhawan
Journal:  J Clin Exp Hepatol       Date:  2020-04-22

Review 2.  Acute Fatty Liver of Pregnancy: Pathophysiology, Anesthetic Implications, and Obstetrical Management.

Authors:  Emily E Naoum; Lisa R Leffert; Hovig V Chitilian; Kathryn J Gray; Brian T Bateman
Journal:  Anesthesiology       Date:  2019-03       Impact factor: 7.892