Literature DB >> 27982678

Disparity between two-dimensional echocardiographic and electroanatomic left and right atrial volumes in patients undergoing catheter ablation for long-standing persistent atrial fibrillation.

L Škňouřil1, Š Havránek, V Bulková, M Dorda, T Paleček, J Šimek, Z Fingrová, A Linhart, J Januška, D Wichterle, M Fiala.   

Abstract

Left atrial (LA) volume (LAV) is used for the selection of patients with atrial fibrillation (AF) to rhythm control strategies. Calculation of LAV from the LA diameters and areas by two-dimensional (2D) echocardiography may result in significant error. Accuracy of atrial volume assessment has never been studied in patients with long-standing persistent AF (LSPAF) and significant atrial remodeling. This study investigated correlation and agreement between 2D echocardiographic (Simpson method) and electroanatomic (CARTO, Biosense Webster) left and right atrial (RA) volumes (LAV(ECHO) vs. LAV(CARTO) and RAV(ECHO) vs. RAV(CARTO)) in patients undergoing catheter ablation for LSPAF. The study enrolled 173 consecutive subjects (females: 21 %, age: 59+/-9 years). There was only modest correlation between LAV(ECHO) (92+/-31 ml) and LAV(CARTO) (178+/-37 ml) (R=0.57), and RAV(ECHO) (71+/-29 ml) and RAV(CARTO) (173+/-34 ml) (R=0.42), respectively. LAV(ECHO) and RAV(ECHO) underestimated LAV(CARTO) and RAV(CARTO) with the absolute bias (+/-1.96 standard deviation) of -85 (-148; -22) ml and -102 (-169; -35) ml, respectively, and with the relative bias of -48 (-75; -21) % and -59 (-88; -30) %, respectively (all P<0.000001 for their mutual difference). Significant confounders of this difference were not identified. In patients with LSPAF, 2D echocardiography significantly underestimated both LA and RA volumes as compared with electroanatomic reference. This disagreement was independent of clinical, echocardiographic and mapping characteristics.

Entities:  

Mesh:

Year:  2016        PMID: 27982678     DOI: 10.33549/physiolres.933314

Source DB:  PubMed          Journal:  Physiol Res        ISSN: 0862-8408            Impact factor:   1.881


  4 in total

1.  Dielectric-based imaging and navigation of the heart.

Authors:  Albert J Rogers; Sanjiv M Narayan
Journal:  Heart Rhythm       Date:  2019-07-16       Impact factor: 6.343

2.  Changes in LA volume and diameter correlate with mechanisms of recurrence after paroxysmal AF ablation.

Authors:  Eric Buffle; Nicolas Johner; Mehdi Namdar; Dipen Shah
Journal:  Indian Heart J       Date:  2022-03-17

3.  Three dimensional reconstruction to visualize atrial fibrillation activation patterns on curved atrial geometry.

Authors:  Ricardo Abad; Orvil Collart; Prasanth Ganesan; A J Rogers; Mahmood I Alhusseini; Miguel Rodrigo; Sanjiv M Narayan; Wouter-Jan Rappel
Journal:  PLoS One       Date:  2021-04-09       Impact factor: 3.240

4.  3D electroanatomical mapping is less sensitive to atrial remodeling in estimation of true left atrial volume than echocardiography.

Authors:  Zdenka Fingrova; Josef Marek; Stepan Havranek; Lukas Lambert; Petr Kuchynka; Ales Linhart
Journal:  BMC Med Imaging       Date:  2018-09-18       Impact factor: 1.930

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.