| Literature DB >> 27980362 |
Byul Lyu1, Kyu Yeon Hwang2, Sun Young Kim1, Su Young Kim1, Kyung Sun Na1.
Abstract
PURPOSE: The purpose of this multi-institute, single-group clinical trial was to evaluate the effectiveness and safety of toric orthokeratology lenses for the treatment of patients with combined myopia and astigmatism.Entities:
Keywords: Astigmatism; Contact lenses; Myopia; Orthokeratologic procedures; Refraction
Mesh:
Year: 2016 PMID: 27980362 PMCID: PMC5156617 DOI: 10.3341/kjo.2016.30.6.434
Source DB: PubMed Journal: Korean J Ophthalmol ISSN: 1011-8942
Characteristics of the toric orthokeratology lenses used in the trial
D = diopters; UVA = ultraviolet A rays; UVB = ultraviolet B rays.
Fig. 1Numbers of subjects recruited for the study and who dropped out. The reasons for exclusion and drop-out are described. TBUT = tear break-up time.
Spherical and cylindrical refractive errors measured at screening and after 4 weeks of toric orthokeratology lens use
D = diopters; SD = standard deviation; CI = confidence interval.
*Absolute value of the difference between the values at screening and week 4; †Wilcoxon's signed-rank test.
Fig. 2Scattergram showing subject distribution according to myopic refractive error at the time of screening and at the end of the study.
Fig. 3Scattergram showing subject distribution according to astigmatic refractive error at the time of screening and at the end of the study.
Uncorrected and corrected VA values measured at screening and after 4 weeks of toric orthokeratology lens use
VA = visual acuity; logMAR = logarithm of the minimal angle of resolution; SD = standard deviation; CI = confidence interval.
*Absolute value of the difference between the values at screening and week 4; †Wilcoxon's signed rank test.
Fig. 4Typical topographic pattern of corneal astigmatism of subjects at screening (A) and at the end of the study (B). The average corneal astigmatism of subjects decreased from 1.9 to 1.6 diopters. OD = right eye.
Endothelial cell count and CCT measured at screening and after 4 weeks of toric orthokeratology lens use
CCT = central corneal thickness; SD = standard deviation; CI = confidence interval.
*Among the 27 patients (45 eyes) screened, one (two eyes) refused examination of endothelial cell count and CCT at week 4, and one patient (one eye) dropped out; †Absolute difference between the values at screening and week 4; ‡Paired t-test or Wilcoxon's signed-rank test.