Literature DB >> 27980084

Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

Takehiro Izumo1, Yuji Matsumoto1, Shinji Sasada1, Christine Chavez1, Toshiyuki Nakai1, Takaaki Tsuchida1.   

Abstract

OBJECTIVE: The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.
METHODS: Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath.
RESULTS: A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths.
CONCLUSIONS: Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary.
© The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

Entities:  

Keywords:  EBUS-GS; bronchoscopy; ground glass opacity; radial EBUS; rapid on-site evaluation

Mesh:

Year:  2017        PMID: 27980084     DOI: 10.1093/jjco/hyw180

Source DB:  PubMed          Journal:  Jpn J Clin Oncol        ISSN: 0368-2811            Impact factor:   3.019


  10 in total

1.  The many facets of diagnostic bronchoscopy for pulmonary ground glass nodules.

Authors:  Christine Chavez; Takehiro Izumo
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

2.  Feasibility and accuracy of rapid on-site evaluation of touch imprint cytology during transbronchial biopsy.

Authors:  Kohei Shikano; Tsukasa Ishiwata; Fumie Saegusa; Jiro Terada; Masashi Sakayori; Mitsuhiro Abe; Takeshi Kawasaki; Jun Ikari; Naoko Kawata; Yuji Tada; Koichiro Tatsumi
Journal:  J Thorac Dis       Date:  2020-06       Impact factor: 2.895

3.  Diagnostic yield of additional conventional transbronchial lung biopsy following radial endobronchial ultrasound lung biopsy for peripheral pulmonary lesions.

Authors:  Sojung Park; Hee-Young Yoon; Yeji Han; Kyung Sook Wang; So Young Park; Yon Ju Ryu; Jin Hwa Lee; Jung Hyun Chang
Journal:  Thorac Cancer       Date:  2020-04-27       Impact factor: 3.500

4.  Comparison of tumor cell numbers and 22C3 PD-L1 expression between cryobiopsy and transbronchial biopsy with endobronchial ultrasonography-guide sheath for lung cancer.

Authors:  Ken Arimura; Mitsuko Kondo; Yoji Nagashima; Masato Kanzaki; Fumi Kobayashi; Kiyoshi Takeyama; Jun Tamaoki; Etsuko Tagaya
Journal:  Respir Res       Date:  2019-08-16

5.  Improved diagnostic yield of transbronchial lung biopsy in peripheral pulmonary lesions using a combination of endobronchial ultrasound and rapid on-site evaluation.

Authors:  Chunhua Xu; Yan Wang; Wei Wang; Qi Yuan; Hui di Hu; Li Li
Journal:  J Int Med Res       Date:  2021-03       Impact factor: 1.671

6.  Impact of rapid on-site evaluation combined with endobronchial ultrasound and virtual bronchoscopic navigation in diagnosing peripheral lung lesions.

Authors:  Jia-Chao Qi; Liping Liao; Zhiwei Zhao; HuiXue Zeng; Tiezhu Wang; Miaofen Hu; LiJv Wang; Zhi Wu; Yuming Ye; Yangwu Ou; Zhiming Cai; Qiyin Wu; Qiaozhen Xu; Weiliang Zhang; Wensen Huang; Hao Li; Li Lin
Journal:  BMC Pulm Med       Date:  2022-03-31       Impact factor: 3.317

7.  Application of rapid on‑site evaluation in computed tomography‑guided percutaneous transthoracic needle biopsy of pulmonary nodules of ≤2.0 cm in diameter.

Authors:  Dongxu Wang; Qing Zhang; Yuguang Wang; Wei Dou; Guoxu Ding; Qiuting Wen; Ying Han; Youli Du; Bo Li
Journal:  Exp Ther Med       Date:  2022-09-07       Impact factor: 2.751

8.  Rapid On-Site Evaluation During Radial Endobronchial Ultrasound-Guided Transbronchial Lung Biopsy for the Diagnosis of Peripheral Pulmonary Lesions.

Authors:  Chunhua Xu; Wei Wang; Qi Yuan; Huidi Hu; Li Li; Rusong Yang
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec

9.  The Value of Additional Conventional Transbronchial Biopsy in the Negative Results of Rapid On-site Evaluation During Endobronchial Ultrasound With Guide Sheath to Diagnose Small Peripheral Lung Cancer.

Authors:  Takayasu Ito; Shotaro Okachi; Tadasuke Ikenouchi; Futoshi Ushijima; Takamasa Ohashi; Masahiro Ogawa; Masato Nagahama; Naozumi Hashimoto
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec

10.  Effectiveness of convolutional neural networks in the interpretation of pulmonary cytologic images in endobronchial ultrasound procedures.

Authors:  Ching-Kai Lin; Jerry Chang; Ching-Chun Huang; Yueh-Feng Wen; Chao-Chi Ho; Yun-Chien Cheng
Journal:  Cancer Med       Date:  2021-11-01       Impact factor: 4.452

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.