In Vivo Validation of Volume Flow Measurements of Pulsatile Flow Using a Clinical Ultrasound System and Matrix Array Transducer.

John M Hudson1, Ross Williams2, Laurent Milot2, Qifeng Wei3, James Jago3, Peter N Burns4.   

Abstract

The goal of this study was to evaluate the accuracy of a non-invasive C-plane Doppler estimation of pulsatile blood flow in the lower abdominal vessels of a porcine model. Doppler ultrasound measurements from a matrix array transducer system were compared with invasive volume flow measurements made on the same vessels with a surgically implanted ultrasonic transit-time flow probe. For volume flow rates ranging from 60 to 750 mL/min, agreement was very good, with a Pearson correlation coefficient of 0.97 (p < 0.0001) and a mean bias of -4.2%. The combination of 2-D matrix array technology and fast processing gives this Doppler method clinical potential, as many of the user- and system-dependent parameters of previous methods, including explicit vessel angle and diameter measurements, are eliminated.
Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Keywords:  Volume flow

Mesh:

Year:  2016        PMID: 27979667     DOI: 10.1016/j.ultrasmedbio.2016.10.008

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Three-dimensional US for Quantification of Volumetric Blood Flow: Multisite Multisystem Results from within the Quantitative Imaging Biomarkers Alliance.

Authors:  Oliver D Kripfgans; Stephen Z Pinter; Cristel Baiu; Matthew F Bruce; Paul L Carson; Shigao Chen; Todd N Erpelding; Jing Gao; Mark E Lockhart; Andy Milkowski; Nancy Obuchowski; Michelle L Robbin; Jonathan M Rubin; James A Zagzebski; J Brian Fowlkes
Journal:  Radiology       Date:  2020-06-30       Impact factor: 11.105

2.  Comparison of hemodialysis arteriovenous fistula blood flow rates measured by Doppler ultrasound and phase-contrast magnetic resonance imaging.

Authors:  Yong He; Yan-Ting Shiu; Daniel B Pike; Prabir Roy-Chaudhury; Alfred K Cheung; Scott A Berceli
Journal:  J Vasc Surg       Date:  2018-05-18       Impact factor: 4.268

3.  Measurement of Flow Volume in the Presence of Reverse Flow with Ultrasound Speckle Decorrelation.

Authors:  Xiaowei Zhou; Xinhuan Zhou; Chee Hau Leow; Meng-Xing Tang
Journal:  Ultrasound Med Biol       Date:  2019-08-01       Impact factor: 2.998

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.