Literature DB >> 27979292

Determination of cadmium and lead at sub-ppt level in soft drinks: An efficient combination between dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry.

Jaime S Mandlate1, Bruno M Soares2, Tassia S Seeger3, Paula Dalla Vecchia3, Paola A Mello3, Erico M M Flores3, Fabio A Duarte4.   

Abstract

A DLLME method for extraction and preconcentration of Cd and Pb from soft drinks and further determination by GF AAS was developed. Important parameters of DLLME such as the type and volume of dispersive and extraction solvents, concentration of DDTC (complexing agent) and pH were evaluated. Better results were obtained using 500μL of acetone for Cd and 700μL of acetonitrile for Pb as dispersive solvents, 60μL of CCl4 as extraction solvent for both analytes and 500μL of 1.5% DDTC solution. Accuracy was evaluated by recovery assays and ranged from 91 to 113% for Cd and from 95 to 108% for Pb, with RSD below 10 and 7%, respectively. The LODs were 0.006 and 0.072ngL-1 for Cd and Pb, respectively. The optimized method was applied for the determination of Cd and Pb in soft drinks with different brands and flavours.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cadmium determination; Dispersive liquid-liquid microextraction; Graphite furnace atomic absorption spectrometry; Lead determination; Soft drinks

Mesh:

Substances:

Year:  2016        PMID: 27979292     DOI: 10.1016/j.foodchem.2016.11.075

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  5 in total

1.  Methods of liquid phase microextraction for the determination of cadmium in environmental samples.

Authors:  Analú Pires Santos; Maria das Graças Andrade Korn; Valfredo Azevedo Lemos
Journal:  Environ Monit Assess       Date:  2017-08-09       Impact factor: 2.513

2.  Rapid Speciation of Lead in Human Blood and Urine Samples Based on MWCNTs@DMP by Dispersive Ionic Liquid-Suspension-Micro-Solid Phase Extraction.

Authors:  Nafiseh Esmaeili; Jamshid Rakhtshah; Eskandar Kolvari; Alimord Rashidi; Hamid Shirkhanloo
Journal:  Biol Trace Elem Res       Date:  2020-10-09       Impact factor: 3.738

3.  A novel electrochemiluminescence biosensor based on the self-ECL emission of conjugated polymer dots for lead ion detection.

Authors:  Ying He; Xiaoxia Hu; Zhengjun Gong; Shihong Chen; Ruo Yuan
Journal:  Mikrochim Acta       Date:  2020-03-18       Impact factor: 5.833

4.  Graphene Assisted in the Analysis of Coumarins in Angelicae Pubescentis Radix by Dispersive Liquid-Liquid Microextraction Combined with 1H-qNMR.

Authors:  Yanmei Feng; Qian Li; Daiyu Qiu; Guichen Li
Journal:  Molecules       Date:  2021-04-21       Impact factor: 4.411

5.  Total Versus Inorganic and Organic Species of As, Cr, and Sb in Flavored and Functional Drinking Waters: Analysis and Risk Assessment.

Authors:  Wiktor Lorenc; Barbara Markiewicz; Dariusz Kruszka; Piotr Kachlicki; Danuta Barałkiewicz
Journal:  Molecules       Date:  2020-03-01       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.