Literature DB >> 27979082

Magnetic graphene dispersive solid phase extraction combining high performance liquid chromatography for determination of fluoroquinolones in foods.

Xin He1, Geng Nan Wang1, Kun Yang1, Hui Zhi Liu1, Xia Jun Wu1, Jian Ping Wang2.   

Abstract

In this study, a magnetic graphene-based dispersive solid phase extraction method was developed that was combined with high performance liquid chromatography to determine the residues of fluoroquinolone drugs in foods of animal origin. During the experiments, several parameters possible influencing the extraction performance were optimized (amount of magnetic graphene, sample pH, extraction time and elution solution). This extraction method showed high absorption capacities (>6800ng) and high enrichment factors (68-79-fold) for seven fluoroquinolones. Furthermore, this absorbent could be reused for at least 40 times. The limits of detection were in the range of 0.05-0.3ng/g, and the recoveries from the standards fortified blank samples (bovine milk, chicken muscle and egg) were in the range of 82.4-108.5%. Therefore, this method could be used as a simple and sensitive tool to determine the residues of fluoroquinolones in foods of animal origin.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dispersive solid phase extraction; Fluoroquinolones; Foods of animal origin; High performance liquid chromatography; Magnetic graphene

Mesh:

Substances:

Year:  2016        PMID: 27979082     DOI: 10.1016/j.foodchem.2016.11.035

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  3 in total

1.  Magnetic covalent organic frameworks with core-shell structure as sorbents for solid phase extraction of fluoroquinolones, and their quantitation by HPLC.

Authors:  Min Wang; Manjie Gao; Kailian Zhang; Lujun Wang; Wencheng Wang; Qifeng Fu; Zhining Xia; Die Gao
Journal:  Mikrochim Acta       Date:  2019-11-21       Impact factor: 5.833

Review 2.  Application of Graphene and its Derivatives in Detecting Hazardous Substances in Food: A Comprehensive Review.

Authors:  Jinjin Pei; Ting Ren; Yigang Huang; Rui Chen; Wengang Jin; Shufeng Shang; Jinze Wang; Zhe Liu; Yinku Liang; A M Abd El-Aty
Journal:  Front Chem       Date:  2022-07-01       Impact factor: 5.545

3.  Fiberoptic-Coupled Spectrofluorometer with Array Detection as a Process Analytical Chemistry Tool for Continuous Flow Monitoring of Fluoroquinolone Antibiotics.

Authors:  Nader Shokoufi; Maryam Vosough; Mona Rahimzadegan-Asl; Atefeh Abbasi-Ahd; Mahsa Khatibeghdami
Journal:  Int J Anal Chem       Date:  2020-02-07       Impact factor: 1.885